GB
7
2.5) Description of connections
Terminals
Functions
Description
1-2
Phase - Neutral
Mains power input
3
Earth
Control unit earth connection
4
Earth
Motor earth connection
5-6
Motor
36Vdc motor power input
7-8
Encoder
Motor encoder input
9-10
Flashing lamp
24Vdc flashing lamp input max. 25W
11-12
Electrical block/Suction pad 24Vdc electrical block/suction pad output max. 500mA
13-14
Phototest
Phototest output
15-16
24Vdc
24Vdc services power input max. 200mA
17
Common
Common for all inputs
18
Sca
Door open lamp output (on when the door is open, off when it is closed, flashes
slowly during the opening manoeuvre, flashes quickly during the closing manoeuvre)
19
Cor
Courtesy lamp output (switches on when the manoeuvre begins and switches off 60
seconds after the manoeuvre has finished)
20
Man
Maintenance lamp output
21
Stop
Input with STOP function (Emergency, shutdown or extreme safety)
22
Photocell
Input for safety devices (photoelectric cells, pneumatic edges) affecting the closing
manoeuvre
23
Photo 2
Input for safety devices (photoelectric cells, pneumatic edges) affecting the opening
manoeuvre
24
Step-by-step
Input with cyclical Open-Stop-Close-Stop operation
25
Open
Input for opening movement with cyclical Open-Stop-Open-Stop operation
26
Close
Input for closing movement with cyclical Close-Stop-Close-Stop operation
27
Partial open
Input with cyclical Partial Open - Stop - Close- Stop operation
41-42
2° Radio Ch
Output for the second radio receiver channel
43-44
Aerial
Input for the radio receiver aerial
+ -
Battery
24 volt battery connection
Summary of Contents for Mindy A924
Page 2: ...mindy...
Page 3: ...A924...
Page 19: ...19 Nice reserves the right to modify the products whenever it sees fit...