Page 1: ...Nice Apollo Slide Gate Opener Vehicular Slide Gate Operator Revision 1 0 0 0_2 2014 Model 72001K...

Page 2: ......

Page 3: ...MING POWER WIRING 10 11 LIMIT AND MOTOR WIRING 11 12 LIMIT AND MOTOR CONNECTION TO THE BOARD 11 13 SETTING THE LIMIT SWITCHES 12 14 QUICK RELEASE OPERATION 13 15 LEARNING MODE 14 16 ACCESSORY INPUTS A...

Page 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Page 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Page 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Page 7: ...t any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of th...

Page 8: ...r Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections 72001K Control Box Chain Bracket 2 10020715 U Bolts 4 5 16 x 3 U Bolts 4 5 16 x 2 40...

Page 9: ...ning Centerline of gate 6 24 Inside posts 5 Mount operator to posts at desired height using the four supplied 3 U Bolts and tighten into place making sure operator is level 8 CHASSIS MOUNTING 9 CHAIN...

Page 10: ...backwards a red LED will illuminate below the terminal If solar power is to be used it will be necessary to program control board for STANDBY operation See section 16 for information on STANDBY mode...

Page 11: ...below Note If the gate moves in the opposite direction from what is expected reverse the actuator wiring from what is shown Red to Pin 3 Black to Pin 1 Motor wiring Connect the motor leads to the 3 p...

Page 12: ...ard as shown above The fully CLOSED limit switch is now set Note if green LED illuminates reverse orange and white limit wires MOTOR 1 LED RED MOTOR 2 LED RED The limit adjustments are located inside...

Page 13: ...by pulling the handle until the lock pins seperate from the sprocket and turning in either direction a half turn Note If the gate or motor is in a bind the chain could be tight and cause increased pr...

Page 14: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Page 15: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Page 16: ...ting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receiver...

Page 17: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Page 18: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 19 2 Magnetic lock connection...

Page 19: ...ty equipment and connections Clean equipment and connections 20 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 20 7 Poor mechan...

Page 20: ...op Sensors and Photocells Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Loop Safety Loop Safety Loop Exit 4 Min from closed gate 4 Mi...

Page 21: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Page 22: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Page 23: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 24 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Page 24: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Page 25: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Page 26: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Page 27: ...27 1 1 2 2 A A B B COMPANY NICEAPOLLO NAME 7200ETL GENERAL OVERVIEW 14 59 31 50 20 00 75 63 3 50 23 25 63 11 28 21 20 4 81 21 50...

Page 28: ...10037390 1 6 LID 10053890 1 7 NICE RECEIVER 318NPI 1 8 DRIVE SPROCKET 40B17 1 9 FLANGE BEARING UCFL202 2 10 LIMIT SPROCKET QUICK RELEASE 25B24 1 11 IDLER SPROCKET 40BB17H 2 12 FRAME 10003590 1 13 CHA...

Page 29: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Page 30: ...30...

Page 31: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Page 32: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...