Stone caisson
LEK
Frostfritt djup
Frost proof
depth
If the house has a cellar the stone caisson must be posi-
tioned so that condensation water does not affect the
house. Otherwise the stone caisson can be positioned
directly under the heat pump.
The outlet of the condensation water pipe must be at
frost free depth.
Gutter drainage
NOTE
Bend the hose to create a water seal, see illustra-
tion.
LEK
Frostfritt
djup
Water seal
Frost free
depth
Water seal
LEK
From air/water heat
pump
■
The outlet of the condensation water pipe must be at
frost free depth.
■
Route the pipe downward from the air/water heat
pump.
■
The condensation water pipe must have a water seal
to prevent air circulation in the pipe.
■
The installation length can be adjusted by the size of
the water seal.
7
Chapter 2 |
Pipe connections
Condensation water pipe KVR 10