The accessory KVR 10 is used to safely lead away most
of the condensation water from the air/water heat pump
to a frost free collection point.
The accessory is suitable to following products from NIBE:
■
■
F2120
F2016
■
■
F2026
F2300
■
■
HBS 05 + AMS 10
F2030
■
F2040
NOTE
It is important to the heat pump function that
condensation water is led away and that the
drain for the condensation water run off is not
positioned so that it can cause damage to the
house.
The heating cable starts automatically at an outdoor
temperature of 1.5 °C. When the temperature exceeds
2 °C the heating cable switches off again.
Contents (F2016/F2026/F2030/F2120/F2300)
Insulated hose (inner diameter 40 mm)
1 x
Heating cable
1 x
Hose clamp
1 x
Fuse
1 x
Cable ties
6 x
Automatic protection
1 x
Contents (F2040/HBS 05 + AMS 10)
Insulated hose (inner diameter 40 mm)
1 x
Heating cable
1 x
Hose clamp
1 x
Fuse
1 x
Automatic protection
1 x
Plug
3 x
Gasket
1 x
Connection plate
1 x
Cable tie, length 605 mm
1 x
Cable tie, length 270 mm
2 x
Cable tie, length 200 mm
3 x
NOTE
The installation of KVR 10 is critical to the ma-
chine's function. Read the entire manual!