Connection between HBS 05
and VVM
The cable between the units must be connected between
terminal block (X4:1, 2, 3) in HBS 05 and terminal block
for communication (AA3-X4:13, 14, 15) in VVM.
Stripped length of conductor is 6 mm.
NOTE
When installing AMS 10-6 / HBS 05-6, the NIBE
indoor module must have the correct software
version. Please ensure that the indoor module,
in this case, has at least software version v8320.
Connection between HBS 05 and VVM
-EZ101
-BT12
-BT3
-BT15
-BP4
-EB101
-FL10
-QM41
-XL52
-XL53
-XL1
-XL2
-EZ102
-QZ2
-EB15
HBS 05 can communicate with the indoor module (VVM),
by connecting the indoor module to terminal block
X4:1–3 according to the following image:
Innemodul
AA23
F2040
GND
GND
B-
B-
A+
15
14
13
A+
GND
B-
A+
AA3
1
2
3
4
5
6
External
HBS 05
AA23-X4
AA3-X4
25
Chapter 5 |
Electrical connections
HBS 05