Cooling off
Cooling
[P]
Cooling allowed or not allowed.
"On", "Off" or R 1 to 9.
If RG-20 is connected, the set R values (1 – 9) are affected
when cooling is to start and stop. Cooling starts at set R
°C above RG-20 setting and stops at half R °C below. Ex-
ample: At R 2 at FIGHTER 1127 and 22 °C on RG-20,
cooling starts at 24 °C and stops at 23 °C.
Default setting is Off.
In cooling mode with the room sensor RG20, select
"Cooling On". Then press "Inc" to select the R value.
NOTE
Enter the selected values on page 2 of this Installation
instruction. The details are important for service work.
13
FIGHTER 1127
For the Installer
Control (also with accessories)