Drain indoors
Water seal
The condensation water is lead to an indoor drain (sub-
ject to local rules and regulations).
Route the pipe downward from F2040.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
KVR 10 spliced as illustrated. Pipe routing inside house
not included.
Gutter drainage
Frostfritt
djup
LEK
Frost proof depth
Water seal
The outlet of the condensation water pipe must be at
frost free depth.
Route the pipe downward from F2040.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
Caution
If none of the recommended alternatives is
used good lead off of condensation water must
be assured.
Supplied components
LEK
LEK
Filterball (G1").
2 x flexible pipes (DN25, G1")
with 4 x gaskets.
9
Chapter 2 |
Delivery and handling
F2040