Check the connection difference for the thermo-
stat. Check the start temperature hot water in any
indoor module. Check the charge supply and the
particle filter which may be partially clogged.
■
Hot gas temperature exceeds 135 °C. Indicated as
17 in channel S1.
■
Contact refrigeration technician.
Ice build up in the fan collar
NOTE
Only applies in certain areas.
■
Collar heater (channel A14) not activated.
■
Activate the collar heater in channel A14.
Ice build up on the fan blades and front grille
NOTE
Only applies in certain areas.
■
"Deicing fan" (channel A15) not activated.
■
Activate "deicing fan" in channel A15.
Sensor placement
BT28
BT16
BP1
BT3
BT17
BT15
BT14
BT12
BP1
BT3
BT17
BT15
BT14
BT12
High pressure switch (29 bar)
BP1
Temperature sensor, heating medium return line
BT3
Temperature sensor, condenser supply line
BT12
Temperature sensor, hot gas
BT14
Temperature sensor, fluid pipe
BT15
Temperature sensor, evaporator
BT16
Temperature sensor, suction gas
BT17
Ambient temperature sensor
BT28
NIBE™ F2030
Chapter 9 |
Disturbances in comfort
34