30
NIBE BA-SVM 10-200
The thermal circuit breaker (FD1) is accessible behind
the front cover. It is reset by pressing firmly on the
button (FD1-SF2) using a small screwdriver. Press the
button using max. force 15 N (approx. 1.5 kg).
Resetting
Cable key lock
Use a suitable tool to release/lock the cables in the
terminal blocks of the indoor unit.
CAUTION
In the event of thermal protection activation, report
this to an authorised service centre in order to diag-
nose the possible case.
CAUTION
In the event of thermal protection activation, report
this to an authorised service centre in order to diag-
nose the possible cause.
Thermal circuit breaker
The thermal circuit breaker (FD1) cuts off the power
supply to the electric additional heat if the tempera-
ture rises to the approx. 98°C range or drops below
-8°C and can be manually reset.
FD1
FD1-SF2
L1 L2 L3
N PE
The power supply connection is connected to termi-
nal block (X0) through the input on the back of the
unit (UB1). The cable must be dimensioned according
to the applicable standards.
The 400V connection allows for a maximum power
of 9kW to the electric additional heat. The connection
should be made according to the diagram in the user
manual.
Detailed electrical diagram - see subsection “Electri-
cal wiring diagrams”.
Connections
CAUTION
To prevent interference, unscreened communication
cables and/or sensor cables to external connections
must not be laid at a distance less than 20 cm from
high-voltage cables.
CAUTION
The electrical system to which the device will be con-
nected should be built in accordance with current reg-
ulations.
CAUTION
When a 400V connection is used, the maximum pow-
er of the electric module used in the BA-SVM 10-200
unit is 9kW.
CAUTION
In the case of a dual tariff power supply, it is advisa-
ble to connect the neutral wire from the power supply
circuit (meter).
Power supply connection 400V
Diagram - connecting power supply 400V
X0
Remove the
bridge to use dual-
-tariff control.
Section 6 |