Fuse location AG-CH10
F3
Fuse
Part No.
Fuse (F3)
P
tot
(W)
Length
(m)
718 085
T100mA/250V
15
1
518 900*
T250mA/250V
45
3
718 086
T500mA/250V
90
6
*Fitted at the factory.
Connection of heating cable
Connect the heating cable to terminal block PE, N and
L in the enclosed electrical distribution box as illustrated
below:
N
L
1
N
N
2/1
1/2
Ellåda
Värmekabel
Heating cable
Electrical cabinet
F3
Connection of AG-CH10 to the outdoor unit
AG-AA10
Remove the protective cover according to the instruc-
tions in the outdoor unit's installer manual and connect
AG-CH10 via the outdoor unit's top clamps.
Top clamps
The top clamps in AG-AA10 are connected to 1/2 and
N in the earth circuit breaker as well as PE in terminal
block as illustrated below:
N
L
1
N
N
2/1
1/2
Utomhusenhet
Ellåda
Electrical cabinet
Outdoor unit
F3
Cable routing
The following section describes the recommended cable
routing between the electrical distribution box and the
condensation pipe. Route the heating cable (EB14)
through the lead-in on the underneath. Transition
between electrical cable and heating cable must occur
as illustrated.
1. Locate the connection for AG-CH10 on the outdoor
unit.