NI 9866 Operating Instructions Manual Download Page 1

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for 9866

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...OPERATING INSTRUCTIONS NI 9866 1 Port LIN Module Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...to be installed The latest version of the NI XNET software is at ni com downloads Note The safety guidelines and specifications in this document are specific to the NI 9866 The other components in yo...

Page 4: ...is component may result in bodily injury Safety Guidelines for Hazardous Locations The NI 9866 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC...

Page 5: ...EN 60529 Caution For Zone 2 applications install a protection device between the LIN signals and the NI 9866 LIN pins The device must prevent the LIN Port to COM voltage from exceeding 55 V if there i...

Page 6: ...nd to one or both COM pins The port also has an optional shield pin SHLD that you can connect to a shielded LIN cable Connecting SHLD may improve signal integrity and EMC performance in a noisy enviro...

Page 7: ...is listed in Table 1 Table 1 Pin Assignments for the NI 9866 Connector Pin Signal 1 No Connection NC 2 NC 3 COM 4 NC 5 SHLD 6 COM 7 LIN 8 NC 9 VSUP 6 7 8 9 1 2 3 4 5 Artisan Technology Group Quality...

Page 8: ...5 s For detailed formulas for calculating this value refer to the Line Characteristics section of the LIN specification Belden cable 3084A and other unterminated CAN Serial quality cables meet these...

Page 9: ...oducts master termination is software selectable you can enable it in the API with the NI XNET Session Interface LIN Termination property NI 9866 Hardware Overview The NI 9866 has one full featured LI...

Page 10: ...are typical for the range 40 to 70 C unless otherwise noted LIN Characteristics Transceiver NXP TJA1028 Max baud rate 20 kbps LIN bus lines voltage 40 to 40 VDC Ext Pwr Supply Required Rx Tx LIN Contr...

Page 11: ...Power consumption from chassis 1 W max active mode Thermal dissipation at 70 C 1 25 W max active mode Physical Characteristics Caution If you need to clean your NI 9866 wipe it with a dry towel The p...

Page 12: ...s equipment This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipmen...

Page 13: ...following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to th...

Page 14: ...e chassis you are using for more information about meeting these specifications Operating temperature 40 to 70 C Storage temperature 40 to 85 C Ingress protection IP 40 Operating humidity 10 to 90 RH...

Page 15: ...ration sinusoidal IEC 60068 2 6 5 g 10 to 500 Hz Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and l...

Page 16: ...Note For EMC compliance operate this product according to the documentation CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Vol...

Page 17: ...is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environ...

Page 18: ...t WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee RoHS National Instruments R...

Page 19: ...way Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at...

Page 20: ...emarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file o...

Page 21: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: