4.1 Using Limiter, Setting Limiter
DP060LM/DP120LM/DP180LM
69
Operation procedure
1.
Push [Limiter] soft-key to select 3: V/F Limiter (or push
+
). Opens the setting
window for the voltage/frequency setting range limit.
2.
The screen for the effective value setting or the peak value setting opens depending on the
signal source setting/output waveform settings made here. Set the voltage setting range limiting
value in the [V] item (effective value setting) and [+Vop]/[
Vop] item (peak value setting).
Effective value setting
Peak value setting
3.
Close the window.
4.1.4
Using Frequency Setting Range Limit
You can limit the range of the frequency setting value for the internal signal source by using the
frequency setting range limit. Even if trying to set a frequency that exceeds the limit, the setting
value is restricted to the limiting value. This can prevent mis-setting when you do not want to set
values outside the range.
The frequency setting range limiting value is common to both 100 V and 200 V ranges.
For the default setting range, see
11.15
.
--------
Notes
------------------------------------------------------------------------------------------------------------
The frequency setting range limit is useful for the prevention of an unintended frequency
setting when a setting value is rapidly increased or decreased by using the shuttle.
-----------------------------------------------------------------------------------------------------------------------------
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...