2.5
Output Cable Connection
DP060LM/DP120LM/DP180LM
17
2.5
Output Cable Connection
Before connecting, check the followings.
Be sure to turn off the power switch of this product and switch off the breaker at the distribution
board, before touching the output terminal. Otherwise, an electric shock might occur.
About output terminal
The output terminal is divided into two terminals, polyphase output terminal and single-phase output
terminal as shown in Figure 2-5. Single-phase output terminal is used in single-phase two-wire
output (1P2W), Polyphase output terminal is used in single-phase three-wire output (1P3W) and
three-phase four-wire (3P4W). Table 2-6 shows the screw sizes of the output terminals of each
model.
Power input
terminal
Sensing input terminal
Sigle-phase output
terminal
Polyphase output
terminal
Used in
1P3W, 3P4W
output.
Used in
1P2W output.
DP060LM / DP120LM
DP180LM
Power input terminal
Sensing input terminal
Single-phase output
terminal
Polyphase output
terminal
Powe input
panel
Output panel
Power input and
output panel
Polyphase output
panel
Figure 2-5 Terminal Block Layout
Power input terminal of this figure is for power input three-phase three-wire.
WARNING
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...