11.29 USB Memory Interface
DP060LM/DP120LM/DP180LM
275
RS232 interface *69 *70
Item
Description or Selection
Factory default
Terminal
D-sub 9-pin (male, UNC #4-40 screw)
Baud rate
9600 / 19200
9600 bps
Terminator
“CR” “LF” / “CR” / “LF”
“CR” “LF”
Parity None/Odd/Even
None
Stop bit
1 / 2
1 bit
Data bit
7 / 8
8 bit
Flow control
None/Hardware/Software
None
*69
:
Binary transmission is not supported.
*70
:
Use a cross cable.
GPIB interface (IEEE488.1 std 1987) *71 *72
Item
Description or Selection
Factory default
Address
0 to 30
2
Terminator “LF”
*71
:
Binary transmission is not supported.
*72
:
Query for the main unit status byte using a serial poll is not supported.
LAN interface (IEEE802.3, LXI 1.4 Core 2011) *73
Item
Description or Selection
Factory default
Terminal RJ-45
modular
jack
Transmission method
Ethernet(100BASE-TX / 10BASE-T)
Communication protocol SCPI-RAW
Terminator “LF”
IP address setting
Auto, Fixed
Auto
*73
:
Binary transmission is not supported.
11.29 USB Memory Interface
Commercial USB memory sticks can be used.
Description
Available memory
*74 USB 1.1 or USB 2.0-compliant product
Connector USB-A
(front
panel)
Format FAT32
Writable/readable
contents
Basic Setting Memory, Sequence, Simulation, arbitrary wave
File operation
*75 Create dedicated directory, rename, load, and save
2-byte characters (Japanese, etc.) are not supported.
*74
:
We do not guarantee that all USB memories can be operational with this product.
*75
:
The time stamp recorded on a file is different from the actual date and time.
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...