11. Specifications
PROGRAMMABLE AC POWER SOURCE
264
11.17 AGC
When the AGC (Automatic Gain Control) is on, the detection point voltage is always measured, and
the output voltage is continuously corrected so that its effective value is equal to the output voltage
setting value. The fluctuation of the detection point voltage can be suppressed even when the load is
fluctuated. The detection point can be switched between the sensing input terminal (remote sensing
on) and the output terminal (remote sensing off). When setting remote sensing to FB, AGC cannot be
set, see
11.16
.
Effective only for AC-INT, AC-VCA, AC-SYNC, DC-INT, and DC-VCA and when the waveform is
sine wave or DC. It is turned off when the Sequence or Simulation is selected. It cannot be selected
when the Autocal is set to on.
All
models
Response time
Within 100 ms (typ.)
(DC/50 Hz/60 Hz, at the rated output voltage)
Operation range
The output voltage setting is 8 V or higher
Calibration range
Within
10 % (difference between the output voltage and measured value)
The output voltage should be within the allowed voltage setting range of the
product.
Accuracy
Within
0.5 V /
1.0 V
(in the case of DC or 40 Hz to 550 Hz, 50 V or higher output voltage, resistance
load, the output current is the maximum current or less)
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...