4.
Advanced Operation
PROGRAMMABLE AC POWER SOURCE
174
Operation procedure
1.
Turn off the output, and enter the AC mode. Following two methods are available.
(a)
Shortcut operation:
+
Every time you press the keys, the mode is switched to AC, ACDC, and DC in this order.
(b)
Press the [Osc] soft-key and select [1:AC/DC]. From the opened menu, select [1: AC].
2.
Press the [Osc] soft-key and select [2:Source]. From the opened menu, select [2: VCA].
3.
Set the [Freq], [Wave], and [Gain] items.
4.
Supply a DC voltage to the external signal input connector.
5.
Turn on the output.