4.
Advanced Operation
PROGRAMMABLE AC POWER SOURCE
168
4.14 Adjusting DC Offset
Even when the output voltage is set to 0 V, the DC offset voltage from several mV to several tens
mV may exist in the output. The DC offset adjustment function can reduce such DC voltage close to
zero.
For the DC offset adjustment, four types of values are retained for each output voltage range and
AC/DC mode. For the polyphase model and polyphase output, the values need to be set for each
phase. The setting range of the DC offset adjustment value is shown in Table 4-12.
Table 4-12 Setting Range of DC Offset Adjustment Value
AC/DC mode
Minimum
value
Maximum
value
Resolution Initial
value
Unit
AC
50.0
+50.0 0.1 0.0 mV
ACDC, DC
250
+250 1 0 mV
Note: The setting range is common to 100 V range and 200 V range.
Operation procedure
1.
Press the [Misc] soft-key and select [2:DC Adjust]. The DC offset adjustment window opens.
2.
«Only for the polyphase output» In the [Target Phs] item, specify the phase to perform the DC
offset adjustment.
Summary of Contents for DP060LM
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL NF Corporation...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP060LM DP120LM DP180LM INSTRUCTION MANUAL DA00059920 004...
Page 4: ......
Page 19: ...DP060LM DP120LM DP180LM 1 1 Outline 1 1 Overview 2 1 2 Series Lineup 2 1 3 Features 3...
Page 24: ......
Page 224: ......
Page 244: ......
Page 264: ......
Page 300: ...11 Specifications PROGRAMMABLE AC POWER SOURCE 282 Figure 11 4 DP180LM Type5L cabinet...