4.20 Amplifying the External Signal Input (Optional)
DP Series
183
4.20 Amplifying the External Signal Input (Optional)
When you select EXT for the signal source, you can output the amplified external signal. Also, when
you select ADD for the signal source, you can output the amplified external signal after the internal
signal is added. For the specifications of the gain setting range and the input voltage range, see
--------
Notes
----------------------------------------------------------------------------------------------------------------
The gain setting value is retained for each of 100 V/200 V ranges.
Within the same range, the same value is retained for the gain setting value, regardless of the
combination of the AC/DC mode and the signal sources (VCA, EXT, ADD).
If the voltage after the external signal is amplified, or if the total voltage of the amplified
external signal and the internal signal exceeds ±220 V (100 V range)/±440 V (200 V range),
the output voltage is clipped at that value.
If the signal source is set to EXT, the calculation is carried out in certain intervals by the
measurement function of this product. Therefore, the measurement operation cycle may
become inappropriate depending on the external signal frequency, resulting in the instable
measured value display. In that case, set [ADD] for the signal source and configure the settings
as below. When the signal source is set to [ADD], the measurement calculation is performed in
optimum interval for the frequency which is set for the internal signal source. This may solve
the instability of the measured value display.
Set the frequency for the internal signal source so that it is equal to the one for the external signal.
Set zero for ACV and DCV.
You cannot amplify the external signal in the polyphase model or polyphase system. Also, you
cannot select EXT or ADD for the signal source.
---------------------------------------------------------------------------------------------------------------------------------
Operation procedure
1.
Input the signal to be amplified from the external signal input connector.
2.
Press the [Osc] soft-key and select [2: Source], then : select [4:EXT] or [5:ADD].
Summary of Contents for DP015S
Page 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Page 2: ......
Page 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Page 4: ......
Page 18: ......
Page 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Page 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Page 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Page 298: ......
Page 300: ......
Page 302: ......
Page 303: ......