34
11. STORAGE – TRANSPORT
Your device must be stored and
transported in its original packaging in
order to protect it from any damage.
The package must be stored in a dry
environment, free of dust and protected
from any chemical compounds.
Ambient conditions for transport and
storage
:
•
Temperature: -10 °C to 40 °C
•
Air humidity: Below 60% without
condensation
12. TECHNICAL SPECIFICATIONS
Box:
Dimensions
Width 250 x Height 340 x
Depth 150 mm
Weight
2.3 kg
Mains power
supply
230 V
~
50 Hz
Fuses
Salt //3.15 A AT (Type M-
205 slow)
pH //1 A AT (Type M-205
slow)
Maximum
output
voltage
7 V
Maximum
output
current
14 A
Consumption
150 W
Cell:
Dimensions
Length 275 x Height
180 mm
Weight
1.3 kg without
electrode
Materials
Transparent
polycarbonate cell
Output:
To be affixed
inside diameter 50
and
outside diameter 63
Salt electrode:
Materials
Titanium treated with precious
metal oxides (as per STERILOR
specifications), in order to
withstand changes in polarity
pH module
Resolution:
0.01
Accuracy:
+/- 0.02
Alarm range:
+/- around the
threshold
Pump flow rates:
Up to 1.8 l/h
Max. injection
point pressure:
2 bar
Temperature:
0 to 40 °C
pH electrode:
Dimension
160 mm/12 mm
pH electrode, plastic housing, solid gel, fibre
junction
2 m ready-made cable and BNC connector
13. GUARANTEES
Device-electrode guarantee
This device is guaranteed against any
manufacturing defect for 3 years from the
delivery date (excluding pH sensor and
peristaltic pump parts).
The user must contact his retailer according to
the after-sales service procedure.
Cut off the guarantee card opposite, without
forgetting to make a copy before sending it
duly completed to the following address
The guarantee card below must be
returned to us no later than 15 days
after commissioning of the device:
Product:
STERILOR Duo
Company:
AS POOL – STERILOR
Address:
ZAC de la Rouvellière
F – 72700 SPAY
Tel.:
+33 (0)2 43 42 39 20
Fax:
+33 (0)2 43 47 98 50
Email:
Site:
www.sterilor.com
Summary of Contents for STERILOR Duo
Page 2: ...2 ...