3. For
Verify schedule
, check the
Always start verification on
check box, then select a day of the week
and a time of day using the drop-down lists.
4. For
Verify Priority
, check one or both of the check boxes if you want I/O operations to be favored over
RAID array verification by the system. You can select either
Favour IO over Surface Scan
or
Favour
IO over Parity Scrub
, or both.
5. For
Verify Rate
, select the preferred verification rate by clicking its selection button. The default is
Lowest
.
Note
When there is high host activity, less spare I/O time is available, which can result in longer
verification times. In this situation, it may become necessary to increase the verification rate so that
arrays are verified more quickly.
6. For
Verify Critical Schedule
, check the
Pause verify during critical hours
check box to have the unit
pause any verification that is in progress during times when the extra I/O and CPU load would be
undesirable.
7. If
Pause verify during critical hours
is checked, use the
Verify Critical hours
drop-down lists and
check boxes to indicate the times and days of the week that are “critical”, so that verification is paused
during these times.
8. Click
Save Settings
.
A message is displayed, informing you that the settings have been updated. Click the
Back
button to return to
the
Home
page.
When a verification utility is running, you can check its progress on the
RAID Array Utility Progress
page (see
Start or Stop RAID Array Verification Immediately
Each array is listed in the
Verify Array Specific Settings
section. Each row contains the
Array name
, the
Custom Schedule Settings
(which displays
Default
when no custom settings are set),
Start
buttons for
surface scan and parity scrub, and a
Customize
link.
►
To manually start RAID array verification:
1. Find the row for the array you wish to verify.
2. Click the
Start
button in either the
Surface Scan
or
Parity Scrub
column.
A message is displayed, informing you that the verification has begun. Click the
Back
button to return to the
Verify RAID Array
page.
Progress can monitored on the
RAID Array Utility Progress
page (see
►
To manually stop RAID array verification:
1. Find the row for the array that you wish to stop verification for (for instance, if it is negatively impacting
host I/O performance).
2. Click the
Stop Verify
button.
A message is displayed, informing you that the verification has stopped. Click the
Back
button to return to the
Verify RAID Array
page.