ENERGY SAVER ENABLED
When enabled, the amplifier goes to Energy Saver Mode when no input signal has been received during a
given time interval. The power consumption is then reduced. When input signal is received again, the
amplifier leaves the Energy Save Mode.
You can adjust the No-signal time interval from 1 minute to 3 hours.
You can adjust the No-signal threshold level from -70 dBFS to
– 60 dBFS.
By default, Energy Saver Mode is disabled.
DPU MODE
See Chapter DPU Digital Patching Unit for NXAMP.
ALERTS LIST
GLOBAL
MAINS1 VOLTAGE(V)
The mains 1 voltage is out
of the limits
Over 276[V] (4x1/4x2)
Under 60[V] or over 276[V]
(4x4)
Automatically shut down
and reboot. After reboot,
Error Screen displayed
until
the
causes
are
removed.
A. The connection
between the power source
and the amplifier might be
wrong.
B. Unstable power source.
Check AC power
connection
MAINS2 VOLTAGE(V)
– ONLY 4X4
The mains 2 voltage is out
of the limits
Under 60[V] or over 276[V]
Automatically shut down
and reboot. After reboot,
Error Screen displayed
until the causes are
removed.
A. The connection between
the power source and the
amplifier might be wrong.
B. Unstable power source.
Check AC power
connection
POWER SUPPLY1 VOLTAGE(V)
The output of the power
supply is out of the limits
Automatically shut down
and reboot. After reboot,
Error Screen displayed
until the causes are
removed.
The power supply unit of
the
amplifier
might
malfunction due to some
unexpected reason.
Call service center
POWER SUPPLY2 VOLTAGE(V)
– ONLY 4X4
The output of the power
supply is out of the limits
Automatically shut down
and reboot. After reboot,
Error Screen displayed until
the causes are removed.
The power supply unit of
the
amplifier
might
malfunction due to some
unexpected reason.
Call service center