![NEXIQ Technologies Brake-Link Manual Download Page 97](http://html.mh-extra.com/html/nexiq-technologies/brake-link/brake-link_manual_1681920097.webp)
- Using the Meritor WABCO ABS Application
Brake-Link™ Meritor WABCO ABS Application 91
7
Brake-Link™ blinks the lamp eight times; it displays eight Xs across the
bottom of the screen to indicate the progress of the test.
Once the test is finished, Brake-Link™ displays
TEST IS COMPLETE
.
Press
to return to the
Tests Menu
.
8
Press
to return to the main menu or
to return to the
Select
Application
screen.
Test Valves
This test cycles the selected modulator valve.
Test selected modulator valve
via menu navigation
:
1
Connect Brake-Link™ to the tractor or trailer and power-up (see “Connect-
ing Brake-Link™ Components”, on page 8). Brake-Link™ boots up and pre-
sents the
Select Application
screen.
Use the
and
keys to select
MERITOR WABCO ABS
; press
.
2
Brake-Link™ displays navigation options; use the
and
keys to
select
MENU NAVIGATION
and press
.
3
Next, Brake-Link™ presents the
Protocol Selection
screen. Use the
and
keys to select the desired option and press
A C T I V A T I N G
W A R N I N G L A M P
O N A N D O F F . . .
X X X X X
S E L E C T A P P L I C A T I O N
G E N E R I C P L C T E S T
B E N D I X / K B / E A T O N A B S
M
E R I T O R W A B C O A B S