![Nexcom EBC-3A1 Series User Manual Download Page 31](http://html.mh-extra.com/html/nexcom/ebc-3a1-series/ebc-3a1-series_user-manual_1681443031.webp)
31
3.3.
Interface Introduce
3.3.1.
RS232
RS232 Interface
4 RS232 serial ports for user interface control, and all RS232 ports are DTE mode.
The pinout direction please refer below table:
Name
Abbreviation
Direction
Transmitted Data
TXD
Output
Received Data
RXD
Input
Clear to Send
CTS
Input
Request to Send
RTS
Output
Data Set Ready
DSR
Input
Data Terminal Ready
DTR
Output
Data Carrier Detect
DCD
Input
Ring Indicator
RI
Input
Common Ground
GND
Common
RS232 Specification
Name
Value
Baud Rate
Up to 500Kbps
Data Bits
5, 6, 7, 8 bits
Parity
None, Even, Odd, Mark, Space
Stop Bits
1, 1.5, 2 bits
RS232 Device Node
Connector
Device node
Pinout Define Section
JCOM4
/dev/ttymxc3
JCOMA
/dev/ttyXRUSB0
JCOMB
/dev/ttyXRUSB1
JCOMC
/dev/ttyXRUSB2
JCOMD
/dev/ttyXRUSB3