Ordering Information

The following information below provides ordering information for NISE 4300.

NISE 4300-6300U System (P/N: 10J00430001X0)

6th generation Intel

®

 Core™ i5-6300U fanless system

NISE 4300-6100U System (P/N: 10J00430000X0)

6th generation Intel

®

 Core™ i3-6100U fanless system

24V, 120W AC to DC power adapter w/o power cord (P/N: 7400120026X00)

Summary of Contents for 10J00430000X0

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published April 2021 www nexcom com IoT Automation Solutions Business Group Industrial Fanless Computer NISE 4300 User Manual ...

Page 2: ...Product Introduction Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NISE 4300 4 Front Panel 4 Rear Panel 5 Mechanical Dimensions 6 Chapter 2 Jumpers and Connectors Before You Begin 7 Precautions 7 Jumper Settings 8 Locations of the Jumpers and Connectors for NISB 4300 9 NISB 4300 9 Top View 9 Bottom View 10 Jumpers 11 LVDS Panel Power Selection 11 Backlight Volume Selection 11 CO...

Page 3: ...d 15 pin 23 Battery Connector 23 EC Debug 24 Fan Connector 24 BIOS FW 25 Chapter 3 System Setup Removing the Chassis Bottom Cover 26 Installing a SO DIMM Memory Module 27 Installing an M 2 Storage Module 28 Installing a Mini PCIe Storage Wi Fi LTE Module 30 Installing a Storage Drive 32 Wall Mounting Instructions 36 Chapter 4 BIOS Setup About BIOS Setup 37 When to Configure the BIOS 37 Default Con...

Page 4: ...NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digital de...

Page 5: ...nd Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry ...

Page 6: ...onsible for the safe packaging of defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repai...

Page 7: ...and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection...

Page 8: ...note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system near water in direct sunlight or near a heating device The load of the system unit does not solely rely for s...

Page 9: ...must be greater than the voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipme...

Page 10: ...ion of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information about c...

Page 11: ...el 886 2 8226 7786 Fax 886 2 8226 7926 Email sales nexcobot com www nexcobot com GreenBase Technology Corp 13F No 922 Chung Cheng Rd Zhonghe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7786 Fax 886 2 8226 7900 Email sales nexcom com tw www nexcom com tw EMBUX Technology Co Ltd 13F No 916 Chung Cheng Rd Zhonghe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7786 Fax 886 2...

Page 12: ...t LongGang District ShenZhen 518112 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang nexcom com tw www nexcom cn NEXCOM United System Service Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200062 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email renwang nexcom com tw www nexcom cn NEXGOL Chongqing 1F Building B4 Electronic 2nd Area Phoenix Lake Industrial P...

Page 13: ...lowing table Item Part Number Description Qty 1 60177A0725X00 NISE 4300 Series Quick Reference Guide VER A 1 2 50311F0326X00 Screw for HDD SSD Flat Head Screw Long Fei F3x5 Nylok Ni Heat Treatment 4 3 50311F0294X00 Screw for Mini PCIe Card I Head Screw Long Fei I2x4 Nylok NIGP 1 4 50311F0530X00 Screw for M 2 Module I Head Screw Long Fei I3x6 ISO ISO w Spring Washer NI 1 5 4NCPM00302X00 Terminal Bl...

Page 14: ...he following information below provides ordering information for NISE 4300 NISE 4300 6300U System P N 10J00430001X0 6th generation Intel Core i5 6300U fanless system NISE 4300 6100U System P N 10J00430000X0 6th generation Intel Core i3 6100U fanless system 24V 120W AC to DC power adapter w o power cord P N 7400120026X00 ...

Page 15: ... generation Intel Core i5 i3 BGA type processor Support 1 x 2 5 SATA HDD 2 x DP and 1 x LVDS internal with independent display support 2 x Intel GbE LAN ports 1 x M 2 B Key socket and 1 x mini PCIe socket 2 x USB 3 0 2 x USB 2 0 2 x RS232 1 x RS232 422 485 with auto flow control Support 24VDC input ATX power mode Panel PC adaptable by request Overview Front View Rear View ...

Page 16: ...independent displays by request Front I O Interface Status LEDs 1 x Power LED 1 x GPIO programmable LED 1 x SATA LED Front I O Interface 1 x ATX power on off switch 1 x 3 pin 24V DC input 2 x Intel I210 IT GbE LAN 1 x Dual USB 2 0 ports 500mA per port 1 x Dual USB 3 0 ports 900mA per port 2 x DP1 2 2 x RS232 COM port 1 x RS232 422 485 COM port GPIO Rear I O Interface 2 x Antenna holes Storage Devi...

Page 17: ...re 20 C to 80 C Relative humidity 10 to 90 non condensing Shock protection HDD 20G half sine 11ms IEC60068 2 27 M 2 50G half sine 11ms IEC60068 2 27 Vibration protection with HDD condition Random 0 5Grms 5 500 Hz IEC60068 2 64 Sinusoidal 0 5Grms 5 500 Hz IEC60068 2 6 Certifications CE approval EN61000 6 2 EN61000 6 4 FCC Class A OS Support List Windows 10 IoT 64 bit Windows 7 Pro 64 bit WES7P 64 b...

Page 18: ...0 ports to connect the system with USB 2 0 1 1 devices USB 3 0 USB 3 0 ports to connect the system with USB 3 0 2 0 devices COM1 and COM2 DB9 port used to connect RS232 compatible devices COM3 DB9 port used to connect RS232 422 485 compatible devices LED Indicators Two LED indicators for displaying the power status and storage activity of the system and one LED for programming GPIO Power Switch Pr...

Page 19: ...International Co Ltd All Rights Reserved 5 NISE 4300 User Manual Chapter 1 Product Introduction Rear Panel Antenna Holes Antenna Holes The external antenna mounting holes are used to mount and connect optional Wi Fi antennas ...

Page 20: ... NEXCOM International Co Ltd All Rights Reserved 6 NISE 4300 User Manual Chapter 1 Product Introduction Mechanical Dimensions 258 97 246 97 237 85 53 91 59 91 145 00 60 00 115 00 104 00 94 00 84 00 60 00 25 00 54 00 ...

Page 21: ...urself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electri...

Page 22: ...e jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin ...

Page 23: ...bottom view of the NISB 4300 main board which is the main board used in NISE 4300 It shows the locations of the jumpers and connectors H10 H11 H7 H8 H12 H13 H9 U17 1 19 1 2 20 19 1 20 2 B10 B9 B2 B1 A9 A10 A1 A2 5 14 4 18 9 1 4 8 1 10 1 C3 C1 C2 A3 A1 A2 1 3 2 72 74 204 1 71 73 203 5 9 1 6 5 9 1 6 NISB4300 4BJ04300B1X10 MADE IN TAIWAN VER B DP1 DP2 LAN1A LAN1B USB1 USB2 LED1 J1 DC24V_IN1 COM2 COM1...

Page 24: ...1 73 203 2 72 74 204 S1 S7 P1 P15 1 15 17 51 2 16 18 52 MH5 3 1 2 20 1 19 2 20 1 19 2 1 6 5 2 1 6 5 10 14 2 13 1 3 1 20 2 19 ESD39 ESD35 5 1 1 4 4 1 1 5 2 6 74 75 1 2 MADE IN TAIWAN NISB4300 4BJ04300B1X10 VER B J2 FAN1 WLED1 INV1 TOUCH1 W_USB1 JPNL_PWR1 JBLT_PWM1 DIMM2 JP16 LVDS1 LVDS2 JCOM2_RI1 JCOM1_RI1 COM3 FRONT1 JP1 FUSB1 JFW1 SATA1 MPCIE1 Bottom View ...

Page 25: ...hapter 2 Jumpers and Connectors Jumpers LVDS Panel Power Selection Connector type 1x3 3 pin header Connector location JPNL_PWR1 Backlight Volume Selection Connector type 1x3 3 pin header Connector location JBLT_PWM1 Pin Settings 1 2 On 3V3 2 3 On 5V Pin Settings 1 2 On 3V3 2 3 On 5V 1 3 1 3 ...

Page 26: ...Jumpers and Connectors COM1 Port Power Setting Connector type 2x3 6 pin header Connector location JCOM1_RI1 COM2 Port Power Setting Connector type 2x3 6 pin header Connector location JCOM2_RI1 1 5 2 6 1 5 2 6 Pin Settings 1 2 On 12V 3 4 On RING 5 6 On 5V Pin Settings 1 2 On 12V 3 4 On RING 5 6 On 5V ...

Page 27: ...Connector type 3 pin terminal block Connector location DC24V_IN1 Pin Definition 1 24V 2 GND 3 CHASSIS GND 1 3 LAN1 and LAN2 Ports Connector type RJ45 port Connector location LAN1A and LAN1B ACT LINK 8 1 Pin Definition Pin Definition 1 LAN_MDI0P 2 LAN_MDI0N 3 LAN_MDI1P 4 LAN_MDI1N 5 LAN_MDI2P 6 LAN_MDI2N 7 LAN_MDI3P 8 LAN_MDI3N 9 LAN_VCC 10 GND 11 LAN_LINK1G 12 LAN_LINK100 13 LAN_ACT _ 14 LAN_ACTPW...

Page 28: ...inition Pin Definition 1 5V 2 USB2_3N 3 USB2_3P 4 GND 5 5V 6 USB2_4N 7 USB2_4P 8 GND 5 1 4 8 USB 3 0 Ports Connector type Dual USB 3 0 ports Connector location USB1 Pin Definition Pin Definition 1 5V 2 USB2_1N 3 USB2_1P 4 GND 5 USB3_RX1_N 6 USB3_RX1_P 7 GND 8 USB3_TX1_N 9 USB3_TX1_P 10 5V 11 USB2_2N 12 USB2_2P 13 GND 14 USB3_RX2_N 15 USB3_RX2_P 16 GND 17 USB3_TX2_N 18 USB3_TX2_P 9 1 5 4 10 13 14 1...

Page 29: ...efinition 1 LANE0_P 2 GND 3 LANE0_N 4 LANE1_P 5 GND 6 LANE1_N 7 LANE2_P 8 GND 9 LANE2_N 10 LANE3_P 11 GND 12 LANE3_N 13 CONFIG1 14 CONFIG2 15 AUX_P 16 GND 17 AUX_N 18 HPD 19 DP_RETURN 20 DP_PWR 2 1 19 20 Pin Definition Pin Definition 1 COM_DCD 2 COM_RXD 3 COM_TXD 4 COM_DTR 5 GND 6 COM_DSR 7 COM_RTS 8 COM_CTS 9 RI COM1 and COM2 Ports Connector type DB 9 port 9 pin D Sub Connector location COM1 and ...

Page 30: ...ternational Co Ltd All Rights Reserved 16 NISE 4300 User Manual Chapter 2 Jumpers and Connectors Pin Definition C1 GPIO LED Green Customer Defined C2 SATA LED Yellow C3 POWER LED Green LED Indicators Connector location LED1 PG ...

Page 31: ... Connector type 1x10 10 pin header Connector location J1 Pin Definition Pin Definition 1 HDD_LED 2 HDD_LED 3 GND 4 STBY_LED 5 POWER_LED Pin Definition Pin Definition 1 GND 2 LPC_PLTRST 3 LPC_CLK 4 LPC_LFRAME 5 LPC_LAD3 6 LPC_LAD2 7 LPC_LAD1 8 LPC_LAD0 9 LPC_SERIRQ 10 VCC3 LED Connector Connector type 1x5 5 pin header Connector location WLED1 1 0 1 1 10 5 1 ...

Page 32: ...1CN 14 GND 15 GND 16 V_INV 17 LVDSA_LDC2P 18 V_INV 19 LVDSA_LDC2N 20 LVDS_DISABLE Pin Definition Pin Definition 1 CH7511_GPIO2 2 CH7511_GPIO3 3 VCC_LCD 4 LVDSB_LDC4P 5 LVDSB_LDC7P 6 LVDSB_LDC4N 7 LVDSB_LDC7N 8 VCC_LCD 9 GND 10 LVDSB_LDC5P 11 LVDSB_LL2CP 12 LVDSB_LDC5N 13 LVDSB_LL2CN 14 GND 15 GND 16 V_INV 17 LVDSB_LDC6P 18 V_INV 19 LVDSB_LDC6P 20 GND LVDS Connector Connector type 2x10 20 pin heade...

Page 33: ...n header Connector location INV1 Pin Definition Pin Definition 1 5V 2 12V 3 12V 4 BKCTRL 5 GND 6 GND 7 BKLEN 7 1 Front Panel Connector Connector type 2x7 14 pin header Connector location FRONT1 1 13 2 14 Pin Definition Pin Definition 1 PWR_LED 2 PWR_LED 3 HDD_LED 4 HDD_LED 5 MAIN_SMBCLK 6 MAIN_SMBDATA 7 3VSB 8 GND 9 SLP_S3 10 PS_ON 11 PWR_BTN 12 GND 13 RST _BTN 14 GND ...

Page 34: ...Internal USB 2 0 Connector Connector type 1x6 6 pin header Connector location W_USB1 Touch Screen Connector Connector type 1x5 5 pin header Connector location TOUCH1 Pin Definition Pin Definition 1 5V 2 USB_8N_C 3 USB_8P_C 4 5 6 GND Pin Definition Pin Definition 1 TOUCH_YD 2 TOUCH_XR 3 SENSE 4 TOUCH_YU 5 TOUCH_XL 1 6 1 5 ...

Page 35: ...PIO Connector Connector type 2x10 20 pin header Connector location JP1 Pin Definition Pin Definition 1 5V 2 USB2N7_L 3 USB2P7_L 4 GND Pin Definition Pin Definition 1 5V 2 5V 3 GPO_0 4 GPI_0 5 GPO_1 6 GPI_1 7 GPO_2 8 GPI_2 9 GPO_3 10 GPI_3 11 GPO_4 12 GPI_4 13 GPO_5 14 GPI_5 15 GPO_6 16 GPI_6 17 GPO_7 18 GPI_7 19 GND 20 GND 1 19 2 20 20 6 8 10 External Connector 4 1 3 5 7 9 Internal Connector ...

Page 36: ...onnector location COM3 External Connector Pin Definition Pin Definition 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 10 GND 1 0 1 1 10 Internal Connector RS232 RS422 RS485 Pin Definition Pin Definition Pin Definition 1 DCD 1 TX 1 RTX 2 RXD 2 TX 2 RTX 3 TXD 3 RX 3 4 DTR 4 RX 4 5 GND 5 GND 5 GND 6 DSR 6 6 7 RTS 7 7 8 CTS 8 8 9 RI 9 9 1 6 5 9 External Connector Internal Connector ...

Page 37: ..._TXN S4 GND S5 SATA1_RXN S6 SATA1_RXP S7 GND P1 VCC3 P2 VCC3 P3 VCC3 P4 GND P5 GND P6 GND P7 VCC5 P8 VCC5 P9 VCC5 P10 GND P11 VCC5 P12 GND P13 VCC12 P14 VCC12 P15 VCC12 SATA Connector 7 pin and 15 pin Connector type Standard Serial ATA 7P and 15P Connector location SATA1 S1 P15 Battery Connector Connector type 1x2 2 pin header Connector location J2 Pin Definition 1 GND 2 3V 1 2 ...

Page 38: ...Jumpers and Connectors EC Debug Connector type 1x3 3 pin header Connector location JP16 Pin Definition 1 GPIO LED Green Customer Defined 2 SATA LED Yellow 3 POWER LED Green 1 3 1 4 Pin Definition 1 GND 2 VCC12 3 FAN1TACH 4 FAN1PWM Fan Connector Connector type 1x4 4 pin header Connector location FAN1 ...

Page 39: ...o Ltd All Rights Reserved 25 NISE 4300 User Manual Chapter 2 Jumpers and Connectors BIOS FW Connector type 2x3 6 pin header Connector location JFW1 1 5 2 6 Pin Definition Pin Definition 1 3VSB 2 GND 3 BIOS_CS 4 BIOS_CLK 5 BIOS_SO 6 BIOS_SI ...

Page 40: ...ng the Chassis Bottom Cover CAUTION CAUTION CAUTION 1 Remove the six mounting screws from the bottom cover 2 With the screws removed lift up the cover and remove it from the chassis Prior to removing the chassis bottom cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage ...

Page 41: ...bottom cover before installing a SO DIMM Installing a SO DIMM Memory Module 1 Locate the SO DIMM socket SO DIMM Socket 2 Insert the module into the socket at an approximately 30 degree angle The ejector tabs at the ends of the socket will automatically snap into the locked position to hold the module in place Memory Module ...

Page 42: ...nual Chapter 3 System Setup 1 Locate the M 2 B key slot on the board 2 Insert the M 2 module into the M 2 slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears into the slot Installing an M 2 Storage Module M 2 B Key Slot M 2 Module ...

Page 43: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 29 NISE 4300 User Manual Chapter 3 System Setup 3 Push the module down and secure it with a screw ...

Page 44: ...stem Setup Installing a Mini PCIe Storage Wi Fi LTE Module 1 Locate the mini PCIe slot on the board Mini PCIe Slot Mini PCIe Module 2 Insert the mini PCIe module into the mini PCIe slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears inside the slot ...

Page 45: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 31 NISE 4300 User Manual Chapter 3 System Setup 3 Push the module down and then secure it with a mounting screw ...

Page 46: ...served 32 NISE 4300 User Manual Chapter 3 System Setup Installing a Storage Drive 1 With the bottom side of the chassis facing up unscrew the six mounting screws from the bottom cover 2 With the screws removed lift up the cover and remove it from the chassis ...

Page 47: ...00 User Manual Chapter 3 System Setup 3 Unscrew the three screws securing the storage bracket then remove the bracket 4 Before installing the storage drive and storage bracket please take note of the orientation of the SATA connector SATA Connector SSD Gold Plated Connector ...

Page 48: ...ystem Setup 5 Place the storage drive onto the bracket and align the mounting holes on the storage drive with the mounting holes on the storage bracket 6 While supporting the storage drive turn the bracket to the other side From the outside of the storage bracket secure the drive in place with screws ...

Page 49: ...tup 8 Secure the bottom cover to the chassis with the six screws 7 Plug the SSD gold plated connector to the SATA connector and secure the bracket with the three screws removed earlier Note If the system memory requirements are greater than 8GB the memory will need to be pre installed during factory assembly ...

Page 50: ... bottom surface 2 Secure the brackets to the system by inserting two retention screws into each bracket Wall Mounting Instructions Wall Mount Bracket Specification of the wall mount screw Four Round Head Screw Long Fei P6 32Tx 1 4 SW7 0 8 w Spring Flat Washer 3 Drill holes in the intended installation surface 4 Align the mounting holes on the sides of the mounting brackets with the predrilled hole...

Page 51: ...is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup o...

Page 52: ...l be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left o...

Page 53: ...tup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Page 54: ... BIOS Vendor Core Version Compliancy Project Version Build Date and Time EC Version Access Level Board Information Board ID Processor Information Name Type Speed ID Stepping Number of Processors Microcode Revision GT Info Memory RC Version Total Memory American Megatrends 5 12 UEFI 2 7 PI 1 6 N430A 0 10 x64 09 12 2019 09 51 38 T 00 7 Administrator Basicline BL2 3100 7100 9100 Skylake ULT Intel R C...

Page 55: ...rence Setting incorrect field values may cause the system to malfunction CPU Configuration This section is used to configure the CPU Advanced Version 2 20 1271 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit When enab...

Page 56: ...tel R SpeedStep tm C states Disabled Disabled Intel SpeedStepTM Enables or disables Intel SpeedStep technology C states Enables or disables CPU C states support for power saving Power Performance This section is used to configure the CPU power management features CPU Power Management Control Enters the CPU Power Management Control submenu Advanced Version 2 20 1271 Copyright C 2019 American Megatr...

Page 57: ...4 Save Exit ESC Exit Set Parameters of Serial Port 1 COMA F81216SEC Super IO Configuration Super IO Chip Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 3 Configuration F81216SEC Serial Port 1 Configuration This section is used to configure serial port 1 Serial Port Enables or disables the serial port Advanced Version 2 20 1271 Copyright C 2019 American Megatrends Inc Aptio Set...

Page 58: ... Serial Port Device Settings Enabled IO 2F8h IRQ 3 Serial Port 3 Configuration This section is used to configure serial port 3 Serial Port Enables or disables the serial port Onboard Serial Port Mode Configures the serial port mode to RS232 RS422 RS485 or RS485 Auto Terminal resistor Enables or disables the terminal resistor Advanced Version 2 20 1271 Copyright C 2019 American Megatrends Inc Aptio...

Page 59: ...n Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Pc Health Status CPU temperature System temperature VCORE 12V 3V VDDQ 5V 100 c 42 c 0 84 V 11 99 V 3 35 V 1 35 V 5 09 V Network Stack Configuration This section is used to configure the network stack settings Network Stack Enables or disables UEFI networ...

Page 60: ...t C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications USB Configuration USB Module Version USB Controllers 1 XHCI USB Device...

Page 61: ...timized Defaults F4 Save Exit ESC Exit System Agent SA Parameters System Agent SA Configuration PCH IO Configuration System Agent SA Configuration System Agent SA parameters PCH IO Configuration PCH IO parameters System Agent SA Configuration This section is used to configure the System Agent SA configuration Chipset Version 2 20 1271 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Co...

Page 62: ...er G3 Configures the power state when power is re applied after a power failure G3 state USB2 0 Power State in Standby Configures the USB 2 0 power state in standby mode USB3 0 Power State in Standby Configures the USB 3 0 power state in standby mode Front USB Power State in Standby Configures the front USB power state in standby mode Chipset Version 2 20 1271 Copyright C 2019 American Megatrends ...

Page 63: ...Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable SATA Device SATA And RST Configuration SATA Controller s SATA Mode Selection SATA1 Port 1 M2_1 Port 0 Enabled AHCI Empty Enabled Empty Enabled SATA Controller s Enables or disables SATA device SA...

Page 64: ...ain Version 2 20 1271 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Set Administrator Password Password Description If ONLY the Administrator s password is set then this only limits access to Setup and is only asked...

Page 65: ...yright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Boot Configuration Setup Prompt Timeout Bootup NumLock State Quiet Boot Boot Option Priorities Boot Option 1 Fast Boot On Disabled UEFI Built in...

Page 66: ...efaults Save as User Defaults Restore User Defaults Boot Override UEFI Built in EFI Shell Launch EFI Shell from filesystem device Discard Changes and Reset To exit the Setup utility and reset without saving the changes select this field then press Enter You may be prompted to confirm again before exiting Save Changes To save changes and continue configuring the BIOS select this field then press En...