N42i.900 termination instruction
LANmark Industry Field Terminable Plug Cat 6A
September 2017 - V1.02
Page 1: ...N42i 900 termination instruction LANmark Industry Field Terminable Plug Cat 6A September 2017 V1 02 ...
Page 2: ...tems info ncs nexans com 1 Slip the cover on the end of the cable Also see assembly instructions printed in the box 2 Remove 2 5 cm of the jacket 3 Remove 1 5 cm of the foil 4 Pull back the pairs to expose the plastic cross 5 Cut off the plastic cross as close to the jacket as possible without damaging the wires using flush side cutters ...
Page 3: ... plug to a minimum 7 Insert the brown and orange pairs into the upper Part of the plug keeping the untwist of the pairs between the jacket and plug to a minimum Cut the wires flush as shown on the instructions printed inside the box 8 Ensure the foil is put back around the pairs Wind the drain wire around the foil 9 Close the connector to crimp the wires Install the 360 shield on the underside of ...