Page 2: ...le of Contents 2 General Information 3 Safety Instructions 4 Product Labels 6 Product Features 7 Interfaces 10 LED Indicators 12 Mounting Options 14 Power Connection 17 Power over Ethernet 19 Grounding 21 Memory Cards and Console Cables 22 I O Module 23 Start up Booting 24 ANS Support Portal 26 EC Declaration of Conformity 27 Accessories 28 ...
Page 3: ...switches Scope of the manual This manual is valid for the Nexans XGigaSwitch series in combination with the current version of the Nexans Device Manager LANactive Manager Version 7 02 The User Manual may include more than one product Part of the content e g some use cases or specifications may only apply to some of them For more information on the exact feature set and specifications see the produ...
Page 4: ...After use the switch and all electronic parts contained in the scope of delivery must be disposed of properly according to legal law at a responsible collection point Accessories Only original accessories may be used Any other accessories are only allowed if they do not impair the safety of the device Packaging Do not throw away the packaging The packaging has been designed for repeated use if not...
Page 5: ...it has been stored or transported at low temperatures and subsequently taken into a warm room To avoid any damage please wait till any moisture condensation has vanished from the unit s surface before switching the unit on The unit is operational only after it has reached the guaranteed operating temperature range see Technical Data on page 8 The same applies also to prior storage at high temperat...
Page 6: ...s are unique and refer to each individual device The information about the respective MAC address is located twice on the switch Once on the bottom side of the device and a second at the front The sticker at the front can also be read when the XGigaSwitch is installed Use the barcodes of the product label with the MAC address and serial number information to simply read in the device lists using c...
Page 7: ...ranteed A separated power supply allows a flexible support of all power budgets Power over Ethernet The latest Power over Ethernet standard IEEE802 3bt enables the remote powering with up to 90W per port Equipment like Wireless LAN Access Points IP Cameras Connected Lighting or Smart Building Systems can be supplied with power from the switch directly The Power over Ethernet functionality can be p...
Page 8: ...ht 1 900g 1 500g Operating Temperature 0 45 C Input Voltage Range 90 264V AC 46 57V DC Power Connector C14 connector L N PE 3 pin connector with plug in screw terminal up to 2 5mm FG Scope of Delivery Power cable 1 5m with Power Connector CEE 7 4 4x stick on pads Documentation 3 Pin Power Connector 4x stick on pads Documentation iOption iOption PoE 6 8P 30W iOption PoE 6 8P 90W Article Number 8830...
Page 9: ...Generated 2021 11 30 Page 9 30 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Product Features Dimensions Figure 3 XGigaSwitch dimensions ...
Page 10: ... of XGigaSwitch DICE 8TP 2SFP AC 1 230V AC Power Connector Type C14 90 264V AC 50 60Hz 6 5A 115V 3 0A 230V 2 RJ45 Port 1 4 1000Base T 1000 100 10 Mbps 3 RJ45 Port 5 8 2 5GBase T 2500 1000 100 Mbps 4 Port 9 10 SFP 1 10 Gbps 5 Console port RJ45 6 MAC Address label 7 Status LEDs Mgmt on front and top 8 I O Interface 9 DIP switches 10 SET Button 11 Memory Card slot Format SD ...
Page 11: ...witch DICE 8TP 2SFP DC 1 54V DC Power Connector see chapter Power Connection on page 17 2 RJ45 Port 1 4 1000Base T 1000 100 10 Mbps 3 RJ45 Port 5 8 2 5GBase T 2500 1000 100 Mbps 4 Port 9 10 SFP 1 10 Gbps 5 Console port RJ45 6 MAC Address label 7 Status LEDs Mgmt on front and top 8 I O Interface 9 DIP switches 10 SET Button 11 Memory Card slot Format SD 12 Grounding Screw ...
Page 12: ...t Blue on Switch is booting Blue flashing Loading firmware Green flashing DHCP running Green on Switch up dynamic IP address Red on Switch started with fixed IP address Memory Card LED MC On SD card detected Off No SD card detected TP Links left side Off No link detected Green on Link detected Green flashing Data traffic detected PoE Status right side Off PoE disabled Yellow on PoE enabled ...
Page 13: ...27 2220 sales ans nexans com LED Indicators TP Links Off No link detected Green on Link detected Green flashing Data traffic detected PoE Status Off PoE disabled Yellow on PoE enabled SFP Links Off No link detected Green on Link detected Green flashing Data traffic detected ...
Page 14: ...ch DICE is the usage as a desktop device The scope of delivery contains four pads to stick on the bottom side of the switch On wall Installation with Hook On Mechanism For an on wall installation different mounting kits are available With the basic mounting plate part number 88646400 the XGigaSwitch DICE can be mounted on the wall toolless Figure 6 Mounting Plate An additional strain relief part n...
Page 15: ... com Mounting Options Figure 8 Mounting Plate with additional strain relief Figure 9 Mounting Plate with strain relief and DICE The XGigaSwitch DICE is mounted via a so called hook on mechanism to the mounting plate Detailed information regarding the installation are written in a separate document ...
Page 16: ...ilable part number 88646402 Figure 10 19 Mounting Kit The adaptors are mounted with the attached screws on the bottom side of the XGigaSwitch DICE DIN Rail Installation For a DIN Rail installation a separate DIN Rail mounting clip part number 88306811 can be used The mounting clip can be fix at the bottom side of the switch For the mounting only the attached screws must be used Figure 11 XGigaSwit...
Page 17: ...s recommended to use the power supply unit offered by Nexans see chapter External Power Supply on page 18Fehler Textmarke nicht definiert In case another power source is used e g a central power supply the enclosed 3 pin connector may be used to connect the XGigaSwitch to the DC power source The following table shows the pin assignment and technical parameter to connect the 3 pin connector Input D...
Page 18: ...les ans nexans com Power Connection External Power Supply Figure 13 Desktop PSU 88646283 Ordering Information Desktop Power Supply 54VDC 240W Article Number 88646283 Output Power 240W Connector Primary C14 Connector Secondary 3 pin plug in terminal Dimension L x W x H 187 x 87 x 39 mm ...
Page 19: ... power supply via TP pairs 4 5 and 7 8 Midspan PSE mode B power supply through an external device via TP pairs 4 5 and 7 8 PoE is using all four pairs 1 2 3 6 4 5 7 8 for power transmission However PoE is backward compatible that means PoE or PoE PDs can be connected and powered The PoE solution will only supply power if an appropriate powered device PD is detected The following functions are chec...
Page 20: ... 44mA 1 4mA IEEE 802 3bt 6 60W 40 51W 36 44mA 9 12mA IEEE 802 3bt 7 75W 51 62W 36 44mA 17 20mA IEEE 802 3bt 8 90W 62 71 3W 36 44mA 26 30mA IEEE 802 3bt Permitted voltage levels The voltage ranges for the supply of switches are defined as follows PoE standard Max output power per port Specified voltage range at the Power Source Equipment PSE Voltage level at the switch min typ max IEEE 802 3af Type...
Page 21: ...of Electrical and Electronics Engineers IEEE IEEE802 3af IEEE802 3at and IEEE802 3bt In case of a centralized power supply that powers multiple switches and thus multiple PoE devices the grounding must be connected next to the central power supply In this case the plus voltage must be grounded by connecting it to the potential equalization of the building The following figure shows the schematic o...
Page 22: ...o the new one The MAC address configuration and firmware will be taken on by the new switch from this SD card So no changes in the network policy or pre setup works need to be made as the system will see same switch as before Ordering Information SD Memory Card with MAC Address SD Memory Card with MAC Address plugged Article Number 88300692 88300696 Delivery Separately in plastic case Pre installe...
Page 23: ...ts One contact is normally open and one normally closed The relay contact outputs are controlled via user configurable setpoints through switch management The setpoints operating parameters and interaction can be set in the Industrial Alarms menu of the switch management Pin Signal 1 Relay contact normally closed contact 2 Relay common pin 3 Relay contact normally opened contact The digital inputs...
Page 24: ...via management access 1 Hold configuration button 3 sec By pressing and holding the pushbutton min 3 seconds the switch will change into the configuration mode which is indicated by the Mgmt LED going out As soon as the Mgmt LED is permanently off the pushbutton must be released A rapidly flashing blue Mgmt LED shows that function number 1 has been selected 2 Briefly press configuration button By ...
Page 25: ...agement module If it receives a valid response from a DHCP server the IP parameters are accepted and the management module can be immediately accessed via the assigned IP address If the switch does not get a response the DHCP request is repeated at increasing time intervals with a maximum interval of approx 30 seconds In case Nexans LANactive Manager with Zero Touch Configuration is available in t...
Page 26: ...p www nexans ans de support and download the latest version of the firmware and the management tool Here you will also find the related release notes and the current versions of management manual If you have any questions or problems please contact us at the following support e mail address support ans nexans com To benefit from individualized and extended product support we recommend concluding a...
Page 27: ...video information and communication technology equipment Part 1 Safety requirements EN 55032 2012 Electromagnetic compatibility of multimedia equipment Emission requirements EN 55024 2016 Information technology equipment Immunity characteristics Limits and methods of measurement EN 61000 3 2 2104 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions EN 61000 3 3 2...
Page 28: ...ory Card with MAC 88300696 SD Memory Card with MAC integrated Nexans FTTO Power Supplies Nexans Part No Description 88646283 Desktop Power Supply 54VDC 240W 88646077 Power Supply for Desk Devices 54VDC 65W Nexans LANactive Manager Nexans Part No Description 88301908 LANactive Manager Single User Licence 88301909 LANactive Manager Company Licence 88301920 LANactive Manager Controller Licence Nexans...
Page 29: ... 1000 Transceiver GI LC E Gigabit Ethernet Multimode Tx Rx 850 850nm 550 m LC duplex DDM Support temp r 40 C 85 C dual fibre 88646016 Nexans SFP 1000 Transceiver SM LC E L10 Gigabit Ethernet Singlemode Tx Rx 1310 1310nm 10 km LC duplex DDM Support temp r 40 C 85 C dual fibre 88646073 Nexans SFP 1000 Transceiver SF3 LC E L10 Gigabit Ethernet Singlemode Tx Rx 1310 1550nm 10 km LC simplex DDM Support...
Page 30: ...Bonnenbroicher Str 2 14 41238 Monchengladbach Germany Tel 49 2166 27 2220 Fax 49 2166 27 2499 Alsembergsesteenweg 2 b3 B 1501 Buizingen Belgium Tel 32 0 2 363 38 00 Fax 32 0 2 365 09 99 ...