Page 1: ...88303960 GigaSwitch V5 TP PSE SFP 2VI 54VDC IND 88303965 GigaSwitch V5 TP SFP 2VI 54VDC IND 88303963 GigaSwitch V5 TP SFP VI 230VAC IND ...
Page 2: ...ome use cases or specifications may only apply to some of them For more information on the exact feature set and specifications see the product s web page and datasheet Target group Planners and installers electrical engineers persons entrusted with setting testing and maintaining Ethernet switches Support If you are not yet a registered user of Nexans Support Portal please register at the Nexans ...
Page 3: ...efits 5 Specifications 6 Dimensions 9 Interface Description 10 Product Labels 12 Safety Instructions 13 DIN Rail Installation 14 Horizontal and Vertical Installation 15 Power Connection 17 Grounding 19 Hardware Installation 20 Power over Ethernet 22 Memory Cards and Console Cable 24 LED Behavior 25 Start up Booting 26 Configuration and Reset Button 27 LANactive Manager 29 GigaSwitch Product List 3...
Page 4: ...imedia equipment Emission requirements EN 55024 2016 Information technology equipment Immunity characteristics Limits and methods of measurement EN 61000 3 2 2104 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions EN 61000 3 3 2013 Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage changes voltage fluctuations and flicker in public low volt...
Page 5: ...stallation The very compact design of the GigaSwitch allows a tool less snap in installation into the standard 45 mm cable duct systems or floor boxes without special mounting accessories The special mounting clip allows also a DIN Rail installation Power over Ethernet Up to 5x connected Ethernet devices can be supplied with Power over Ethernet According to the latest IEEE 802 3at PoE standard up ...
Page 6: ...o IEEE802 3at Number of PoE Uplink Ports 1x PSE PoE acc to IEEE802 3at PoE Mode 30W per Port Mode A Pin 1 2 3 6 Max PoE power budget 150W 120W Diagnostic Functions Interfaces Digital Diagnostics Monitoring Interface Yes Twisted Pair Cable Diagnostic Yes General Dimensions W x H x D 96mm x 45mm x 69mm Installation Depth 35mm Material zinc diecasting stainless steel Colour Pure White like RAL 9010 A...
Page 7: ... 2021 11 17 Page 7 33 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Specifications Low Voltage Directive RoHS 2 2011 65 EU Engineering Standards EN 62368 1 EN 55032 EN 61000 6 2 EN 50581 ...
Page 8: ...ed Pair Cable Diagnostic Yes General Dimensions W x H x D 96mm x 45mm x 69mm Installation Depth 35mm Material zinc diecasting stainless steel Colour Pure White like RAL 9010 Ambient Temperature Operation 25 65 C Storage 25 85 C Relative Humidity 20 90 non condensing Weight 290g MTBF 750 000h Power Supply Input Voltage 85 240V AC typ 230V AC or 110V AC Power Consumption 2 8W standby 4 3W typ 5 5W f...
Page 9: ...Generated 2021 11 17 Page 9 33 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Dimensions DIMENSIONS Figure 1 LANactive GigaSwitch dimensions ...
Page 10: ...s PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin power connection 6 Port 6 RJ45 Uplink PoE PSE 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling 88303965 Number Description 1 Port 1 4 RJ45 User Ports PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin power connection 6 Port 6 RJ45 Uplink 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling...
Page 11: ...2166 27 2220 sales ans nexans com Interface Description 88303963 Number Description 1 Port 1 4 RJ45 User Ports 2 Memory card slot microSD 3 Grounding terminal 4 Function input 5 3 pin AC power connection 6 Port 6 RJ45 Uplink 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling ...
Page 12: ...e and refer to each individual device The information about the respective MAC address is located twice on the switch Once on the bottom side of the device and a second time below the labelling of the user ports The sticker below the labelling can also be read when the GigaSwitch is installed Use the barcodes of the product label with the MAC address and serial number information to simply read in...
Page 13: ...e scope of delivery must be disposed of properly according to legal law at a responsible collection point ATTENTION Electrical damage For device protection connect a thermomagnetic fuse CAUTION Danger due to electric shock Never work with applied voltage Packaging Do not throw away the packaging The packaging has been designed for repeated use if not damaged during transport Only the original pack...
Page 14: ...DIN RAIL INSTALLATION Figure 4 DIN Rail Mounting Kit for GigaSwitch The DIN Rail Mounting Kit allows an easy and fast installation of Nexans GigaSwitch on the 35mm DIN Rail in electrical cabinets The switch can be mounted in horizontal and vertical position See page 15 how to turn the ports Figure 5 DIN Rail Mounting Options ...
Page 15: ...ch is designed primarily for installation in parapet and cable ducts with horizontal guidance The low overall height and the vertical guidance of the connection lines extend the range of use also to underfloor systems e g floor boxes The switches feature a rotating switch head with Power over Ethernet function The head of the switch with RJ45 connectors can be mounted vertically or horizontally Th...
Page 16: ...Generated 2021 11 17 Page 16 33 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Horizontal and Vertical Installation 1 2 3 4 5 6 7 8 ...
Page 17: ...ON Pin assignment of the 3 pin DC connector Figure 6 DC Pin assignment Figure 7 DC Power connection In any case please check the correct pin assignment and the correct polarity of the wiring at the supply unit Input DC Voltage typ V Diameter mm Diameter mm AWG Length mm FG 54V DC 0 75 2 5 0 75 2 5 19 12 8 Figure 8 DC Power connection ...
Page 18: ...he 3 pin AC connector Figure 9 AC Pin assignment Figure 10 AC Power connection In any case please check the correct pin assignment and the correct polarity of the wiring at the supply unit Input DC Voltage typ V Diameter mm Diameter mm AWG Length mm Torque Nm PE L N 230V AC 0 14 1 5 0 14 1 5 28 16 7 0 22 0 25 Figure 11 AC Power connection ...
Page 19: ... of the building This is required because the positive voltage is permanently enabled by the GigaSwitch The following figure shows the schematic of grounding the plus voltage Figure 12 Block diagram of grounding The switch can be grounded locally with the grounding terminal of the housing or connected to the central grounding by using a three wired cable Ground Never use the minus voltage for grou...
Page 20: ...e DIN Rail Mounting Kit 2 Note the assignment of the connector The connection plug is included in the scope of delivery 3 Remove the dust caps from the SFP slot Plug the SFP module into the SFP slot and lock it 4 Remove the dust caps from the SFP modules 5 Connect the SFP module to the corresponding LC duplex fibre optic patch cable 6 Use only the supplied microSD card Insert the memory card into ...
Page 21: ...e GigaSwitch is a screw on type Use a screwdriver to fix the connector to the switch 9 Guide the switch with connected cables into the mounting kit until the switch is engaged 10 Switch on the power and check the power LED of the switch 11 Check the Uplink LED it lights up green and flashes if the switch has connectivity 12 Connect the end devices and check the corresponding LED for link and data ...
Page 22: ...t PSE mode A power supply via TP pairs 1 2 and 3 6 Endpoint PSE mode B power supply via TP pairs 4 5 and 7 8 Midspan PSE mode B power supply through an external device via TP pairs 4 5 and 7 8 The PoE solution will only supply power if an appropriate powered device PD is detected The following functions are checked prior to enabling PoE power supply The active PSE source identifies the powered dev...
Page 23: ... output power at PSE Available power at PD Classification signature PoE standard 0 15 4 W 0 44 12 96 W 0 4 mA IEEE 802 3af at 1 4 W 0 44 3 84 W 9 12 mA IEEE 802 3af at 2 7 W 3 84 6 49 W 17 20 mA IEEE 802 3af at 3 15 4 W 6 49 12 95 W 26 30 mA IEEE 802 3af at 4 30 W 12 95 25 50 W 35 45 mA IEEE 802 3at Permitted voltage levels The voltage ranges for the supply of switches are defined as follows PoE s...
Page 24: ...MAC address configuration and firmware will be taken on by the new GigaSwitch In this case no changes in the network policy or pre setup works need to be done because the system will see the same switch as before Nexans Part No Description 88300691 microSD Card with MAC 88300693 microSD Card with MAC integrated Console configuration cables The V 24 console port on Nexans switches allows you to con...
Page 25: ...ng Green flashing Switch is up not yet received a valid IP address Green on Switch is up and has a valid IP address Red on Switch is up with fixed IP address 2 Off No memory card detected Blue on Switch is booting with configuration from memory card Green on Switch is up current flash configuration is mirrored to the memory card 3 Off No link detected Green on Link detected Green flashing Data tra...
Page 26: ...guration In combination with Nexans LANactive Manager Controller version all Nexans GigaSwitch V5 systems support Zero Touch Configuration ZTC With ZTC the configuration process and the programming of firmware upgrades can be fully automized If ZTC is enabled new switch configurations and firmware will automatically be provided by the Zero Touch Configuration Controller subsequently referred as LA...
Page 27: ...e individually disabled via the management in order to prevent an accidental or deliberate manipulation by the user However after disabling these options a reset of the switch to factory default settings is only possible via management access If no access is possible via the management feature e g because name or password are unknown or the VLANs are configured wrongly the switch can nevertheless ...
Page 28: ...lash configuration 2 Lights red Booting with fixed IP address 172 23 44 111 3 Lights white Booting with factory default settings 4 Lights cyan Booting with customer default settings 5 Lights magenta Booting without customer default settings 3 Hold configuration pushbutton 3 sec In order to execute the selected function the pushbutton must be pressed and held for at least 3 seconds The Management L...
Page 29: ...cess Zero Touch Configuration Nexans Part No Description 88301908 LANactive Manager Single User Licence 88301909 LANactive Manager Company Licence 88301920 LANactive Manager Controller Licence Zero Touch Configuration Nexans LANactive Zero Touch Configuration is a contemporary way of designing building and operating networks with minimum effort The use of LANactive GigaSwitches together with the L...
Page 30: ... Security RSTP MSTP SCP QoS VLANs GigaSwitch V5 TP SFP 2VI 54VDC IND Nexans article number 88303965 GigaSwitch V5 TP SFP 2VI 44 57V DC WxHxD mm 90 x 45 x 69 35 Temp range 25 C 65 C Toolless Click in User Ports 4x 10 100 1000 Uplink 1x 10 100 1000 TP 2x 100 1000 SFP PoE 4x 30W IEEE 802 3at 120W WEB Telnet SSHv2 SNMP LANactive Manager Security RSTP MSTP SCP QoS VLANs GigaSwitch V5 TP SFP VI 230VAC I...
Page 31: ...ex DDM Support temp r 40 C 85 C dual fibre Budget 16 dB 88646012 Nexans SFP 100 Transceiver SM LC E L40 Fast Ethernet Singlemode TX RX 1310 1310 40 km LC duplex DDM Support temp r 40 C 85 C dual fibre Budget 30 dB 88646013 Nexans SFP 100 Transceiver SM LC E L80 Fast Ethernet Singlemode TX RX 1550 1550 80 km LC duplex DDM Support temp r 40 C 85 C dual fibre Budget 30 dB 88645914 Nexans SFP 100 Tran...
Page 32: ...it Ethernet Singlemode TX RX 1550 1550 80 km LC duplex DDM Support temp r 40 C 85 C dual fibre Budget 24 dB 88646019 Nexans SFP 1000 Transceiver SM LC E L120 Gigabit Ethernet Singlemode TX RX 1550 1550 120 km LC duplex DDM Support temp r 40 C 85 C dual fibre Budget 29 dB 88646073 Nexans SFP 1000 Transceiver SF3 LC E L10 Gigabit Ethernet Single fiber BiDi Modules Singlemode TX RX 1310 1550 10 km LC...
Page 33: ...Bonnenbroicher Str 2 14 41238 Monchengladbach Germany Tel 49 2166 27 2220 Fax 49 2166 27 2499 Alsembergsesteenweg 2 b3 B 1501 Buizingen Belgium Tel 32 0 2 363 38 00 Fax 32 0 2 365 09 99 ...