Nexans 88303910 User Manual Download Page 1

 

88303910 

GigaSwitch V5 TP(PSE+) SFP-2VI 54VDC 

88303920 

GigaSwitch V5 TP SFP-2VI 54VDC 

88303990 

GigaSwitch V5 2TP(PSE+) SFP-VI 54VDC 

88303991 

GigaSwitch V5 2TP(PD-F+) SFP-VI 54VDC 

88303992 

GigaSwitch V5 2TP SFP-VI 54VDC 

88303971 

GigaSwitch V5 SFP-2VI 230VAC 

88303975 

GigaSwitch V5 TP SFP-VI 230VAC

 

 

Summary of Contents for 88303910

Page 1: ...88303920 GigaSwitch V5 TP SFP 2VI 54VDC 88303990 GigaSwitch V5 2TP PSE SFP VI 54VDC 88303991 GigaSwitch V5 2TP PD F SFP VI 54VDC 88303992 GigaSwitch V5 2TP SFP VI 54VDC 88303971 GigaSwitch V5 SFP 2VI 230VAC 88303975 GigaSwitch V5 TP SFP VI 230VAC ...

Page 2: ... operation of the GigaSwitch V5 series It may include more than one product Part of the content e g some use cases or specifications may only apply to some of them For more information on the exact feature set and specifications see the product s web page and datasheet Target group Planners and installers of FTTO solutions electrical engineers persons entrusted with setting testing and maintaining...

Page 3: ...tions 6 Dimensions 11 Interface Description 12 Product Labels 16 Safety Instructions 17 Installation of FTTO switches 18 Horizontal and Vertical Installation 19 Power Connection 21 Grounding 23 Hardware Installation 24 Installation Distances 26 Power over Ethernet 27 Memory Cards and Console Cable 29 LED Behavior 30 Start up Booting 31 Configuration and Reset Button 32 LANactive Manager 34 GigaSwi...

Page 4: ...o information and communication technology equipment Part 1 Safety requirements EN 55032 2012 Electromagnetic compatibility of multimedia equipment Emission requirements EN 55024 2016 Information technology equipment Immunity characteristics Limits and methods of measurement EN 61000 3 2 2104 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic current emissions EN 61000 3 3 2013 ...

Page 5: ... the version the LANactive GigaSwitch supports Power over Ethernet PoE functionality Devices like VoIP Phones Wireless Access Points and IP Cameras can be directly supplied with power from the switch according to IEEE802 3at The Power over Ethernet functionality can be parameterized controlled and monitored via switch management Memory Card The optional memory card automatically saves the complete...

Page 6: ...o Polarity Eco Mode for RJ45 Ports Yes Rotatable Head Module Yes Power over Ethernet Number of PoE User Ports 4x PoE PSE acc to IEEE802 3at Number of PoE Uplink Ports 1x PoE PSE acc to IEEE802 3at PoE Mode 30W per Port Mode A Pin 1 2 3 6 Max PoE power budget 150W 120W Diagnostic Functions Interfaces Digital Diagnostics Monitoring Interface Yes Twisted Pair Cable Diagnostic Yes General Dimensions W...

Page 7: ... Power Supply Input Voltage 46 57V DC typ 54V DC Power Consumption 4 4W typical 6 2W max Heat Output 22Btu IT h Connector 3 pin connector up to 2 5mm FPE CE Conformity Electro Magnetic Capability Directive 2014 30 EU Low Voltage Directive RoHS 2 2011 65 EU Engineering Standards EN 62368 1 EN 55032 EN 55024 EN 50581 ...

Page 8: ... Rotatable Head Module Yes Power over Ethernet Number of PoE User Ports 4x PoE PSE acc to IEEE 802 3at Number of PoE Uplink Ports 2x PoE PSE acc to IEEE802 at 1x PoE PD 1x PoE PSE acc to IEEE802 at PoE Mode 30W per Port Mode A Pin 1 2 3 6 Max PoE power budget with ext PS 150W 120W Max PoE power budget as PD 19 5W Diagnostic Functions Interfaces Digital Diagnostics Monitoring Interface Yes Twisted ...

Page 9: ...typ 54V DC PoE acc to IEEE802 3at or 46 57V DC typ 54V DC 46 57V DC typ 54V DC Power Consumption 5 3W typ 6 2W fully connected Heat Output 22 Btu IT h Connector 3 pin connector up to 2 5mm FPE CE Conformity Electro Magnetic Capability Directive 2014 30 EU Low Voltage Directive RoHS 2 2011 65 EU Engineering Standards EN 62368 1 EN 55032 EN 55024 EN 50581 ...

Page 10: ...nostic Functions Interfaces Digital Diagnostics Monitoring Interface Yes Twisted Pair Cable Diagnostic Yes General Dimensions W x H x D 90mm x 45mm x 69mm Installation Depth 35mm Material zinc diecasting stainless steel Colour Pure White like RAL 9010 Ambient Temperature Operation 0 45 C Storage 20 85 C Relative Humidity 20 90 non condensing Weight 290g MTBF 750 000h Power Supply Input Voltage 85 ...

Page 11: ...Generated 2021 11 17 Page 11 38 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Dimensions DIMENSIONS Figure 1 LANactive GigaSwitch dimensions ...

Page 12: ...s PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin power connection 6 Port 6 RJ45 Uplink PoE PSE 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling 88303920 Number Description 1 Port 1 4 RJ45 User Ports PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin power connection 6 Port 6 RJ45 Uplink 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling...

Page 13: ...ot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin DC power connection 6 Port 6 RJ45 Uplink PoE PSE 7 Port 5 RJ45 Uplink PoE PSE 8 Status LEDs 9 Labelling 88303991 Number Description 1 Port 1 4 RJ45 User Ports PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin DC power connection 6 Port 6 RJ45 Uplink PoE PSE 7 Port 5 RJ45 Uplink PoE PD 8 Status LEDs 9 Labe...

Page 14: ...7 2220 sales ans nexans com Interface Description 88303992 Number Description 1 Port 1 4 RJ45 User Ports PoE PSE 2 Memory card slot microSD 3 Grounding terminal 4 Port 7 SFP Uplink 5 3 pin DC power connection 6 Port 6 RJ45 Uplink 7 Port 5 RJ45 Uplink 8 Status LEDs 9 Labelling ...

Page 15: ...rts 2 Memory card slot microSD 3 Grounding terminal 4 Function input 5 3 pin AC power connection 6 Port 6 SFP Uplink 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling 88303975 Number Description 1 Port 1 4 RJ45 User Ports 2 Memory card slot microSD 3 Grounding terminal 4 Function input 5 3 pin AC power connection 6 Port 6 RJ45 Uplink 7 Port 5 SFP Uplink 8 Status LEDs 9 Labelling ...

Page 16: ...e and refer to each individual device The information about the respective MAC address is located twice on the switch Once on the bottom side of the device and a second time below the labelling of the user ports The sticker below the labelling can also be read when the GigaSwitch is installed Use the barcodes of the product label with the MAC address and serial number information to simply read in...

Page 17: ...e scope of delivery must be disposed of properly according to legal law at a responsible collection point ATTENTION Electrical damage For device protection connect a thermomagnetic fuse CAUTION Danger due to electric shock Never work with applied voltage Packaging Do not throw away the packaging The packaging has been designed for repeated use if not damaged during transport Only the original pack...

Page 18: ...d according to individual needs Full flexibility Nexans FTTO switches can be combined with a variety of standard installation materials from various international manufacturers All FTTO switches can be easily used with the mounting frames covers and profiles Furthermore Nexans offers its own universal mounting accessories to simplify the installation assembly and disassembly of the devices and to ...

Page 19: ...es are designed primarily for installation in parapet and cable ducts with horizontal guidance The low overall height and the vertical guidance of the connection lines extend the range of use also to underfloor systems e g floor boxes The switches feature a rotating switch head with Power over Ethernet function The head of the switch with RJ45 connectors can be mounted vertically or horizontally T...

Page 20: ...Generated 2021 11 17 Page 20 38 Contact Nexans LAN Systems Tel 49 0 2166 27 2220 sales ans nexans com Horizontal and Vertical Installation 1 2 3 4 5 6 7 8 ...

Page 21: ... Pin assignment of the 3 pin DC connector Figure 10 DC Pin assignment Figure 11 DC Power connection In any case please check the correct pin assignment and the correct polarity of the wiring at the supply unit Input DC Voltage typ V Diameter mm Diameter mm AWG Length mm FG 54V DC 0 75 2 5 0 75 2 5 19 12 8 Figure 12 DC Power connection ...

Page 22: ...e 3 pin AC connector Figure 13 AC Pin assignment Figure 14 AC Power connection In any case please check the correct pin assignment and the correct polarity of the wiring at the supply unit Input DC Voltage typ V Diameter mm Diameter mm AWG Length mm Torque Nm PE L N 230V AC 0 14 1 5 0 14 1 5 28 16 7 0 22 0 25 Figure 15 AC Power connection ...

Page 23: ... of the building This is required because the positive voltage is permanently enabled by the GigaSwitch The following figure shows the schematic of grounding the plus voltage Figure 16 Block diagram of grounding The switch can be grounded locally with the grounding terminal of the housing or connected to the central grounding by using a three wired cable Ground Never use the minus voltage for grou...

Page 24: ...ovable 2 Note the assignment of the connector The connection plug is included in the scope of delivery 3 Remove the dust caps from the SFP slot Plug the SFP module into the SFP slot and lock it 4 Remove the dust caps from the SFP modules 5 Connect the SFP module to the corresponding LC duplex fibre optic patch cable 6 Use only the supplied microSD card Insert the memory card into memory card slot ...

Page 25: ...he GigaSwitch is a screw on type Use a screwdriver to fix the connector to the switch 9 Guide the switch with connected cables into the cable duct until the switch is engaged 10 Switch on the power and check the power LED of the switch 11 Check the Uplink LED it lights up green and flashes if the switch has connectivity 12 Connect the end devices and check the corresponding LED for link and data ...

Page 26: ...end on material and arrangement Below are guidelines for minimum distance between both devices Distance Description Plastic cable ducts mm Metal cable ducts mm A Distance between device beakers with GigaSwitch and Click In power supply with 70W output power 150 100 A Distance between device beakers with GigaSwitch and Click In power supply with 130W output power 200 150 Figure 17 Installation dist...

Page 27: ...t PSE mode A power supply via TP pairs 1 2 and 3 6 Endpoint PSE mode B power supply via TP pairs 4 5 and 7 8 Midspan PSE mode B power supply through an external device via TP pairs 4 5 and 7 8 The PoE solution will only supply power if an appropriate powered device PD is detected The following functions are checked prior to enabling PoE power supply The active PSE source identifies the powered dev...

Page 28: ... output power at PSE Available power at PD Classification signature PoE standard 0 15 4 W 0 44 12 96 W 0 4 mA IEEE 802 3af at 1 4 W 0 44 3 84 W 9 12 mA IEEE 802 3af at 2 7 W 3 84 6 49 W 17 20 mA IEEE 802 3af at 3 15 4 W 6 49 12 95 W 26 30 mA IEEE 802 3af at 4 30 W 12 95 25 50 W 35 45 mA IEEE 802 3at Permitted voltage levels The voltage ranges for the supply of switches are defined as follows PoE s...

Page 29: ...MAC address configuration and firmware will be taken on by the new GigaSwitch In this case no changes in the network policy or pre setup works need to be done because the system will see the same switch as before Nexans Part No Description 88300691 microSD Card with MAC 88300693 microSD Card with MAC integrated Console configuration cables The V 24 console port on Nexans switches allows you to con...

Page 30: ...ng Green flashing Switch is up not yet received a valid IP address Green on Switch is up and has a valid IP address Red on Switch is up with fixed IP address 2 Off No memory card detected Blue on Switch is booting with configuration from memory card Green on Switch is up current flash configuration is mirrored to the memory card 3 Off No link detected Green on Link detected Green flashing Data tra...

Page 31: ...guration In combination with Nexans LANactive Manager Controller version all Nexans GigaSwitch V5 systems support Zero Touch Configuration ZTC With ZTC the configuration process and the programming of firmware upgrades can be fully automized If ZTC is enabled new switch configurations and firmware will automatically be provided by the Zero Touch Configuration Controller subsequently referred as LA...

Page 32: ...e individually disabled via the management in order to prevent an accidental or deliberate manipulation by the user However after disabling these options a reset of the switch to factory default settings is only possible via management access If no access is possible via the management feature e g because name or password are unknown or the VLANs are configured wrongly the switch can nevertheless ...

Page 33: ...lash configuration 2 Lights red Booting with fixed IP address 172 23 44 111 3 Lights white Booting with factory default settings 4 Lights cyan Booting with customer default settings 5 Lights magenta Booting without customer default settings 3 Hold configuration pushbutton 3 sec In order to execute the selected function the pushbutton must be pressed and held for at least 3 seconds The Management L...

Page 34: ...cess Zero Touch Configuration Nexans Part No Description 88301908 LANactive Manager Single User Licence 88301909 LANactive Manager Company Licence 88301920 LANactive Manager Controller Licence Zero Touch Configuration Nexans LANactive Zero Touch Configuration is a contemporary way of designing building and operating networks with minimum effort The use of LANactive GigaSwitches together with the L...

Page 35: ...aSwitch V5 2TP PSE SFP VI 54VDC Nexans article number 88303990 GigaSwitch V5 2TP PSE SFP VI 44 57V DC WxHxD mm 96 x 45 x 69 35 Toolless Click in User Ports 4x 10 100 1000 Uplink 2x 10 100 1000 TP PSE 1x 100 1000 SFP PoE 6x 30W IEEE 802 3at 150W WEB Telnet SSHv2 SNMP LANactive Manager Security RSTP MSTP SCP QoS VLANs GigaSwitch V5 2TP PD F SFP VI 54VDC Nexans article number 88303991 GigaSwitch V5 2...

Page 36: ... x 69 35 Toolless Click in User Ports 4x 10 100 1000 Uplink 2x 100 1000 SFP PoE no support WEB Telnet SSHv2 SNMP LANactive Manager Security RSTP MSTP SCP QoS VLANs GigaSwitch V5 TP SFP VI 230VAC Nexans article number 88303975 GigaSwitch V5 TP SFP VI 110 240V AC WxHxD mm 94 x 45 x 69 35 Toolless Click in User Ports 4x 10 100 1000 Uplink 1x 10 100 1000 TP 1x 100 1000 SFP PoE no support WEB Telnet SS...

Page 37: ...50 850 550 m LC duplex DDM Support temp r 20 C 85 C dual fibre Budget 9 dB 88646016 Nexans SFP 1000 Transceiver SM LC E L10 Gigabit Ethernet Singlemode TX RX 1310 1310 10 km LC duplex DDM Support temp r 40 C 85 C dual fibre Budget 12 dB 88646073 Nexans SFP 1000 Transceiver SF3 LC E L10 Gigabit Ethernet Single fiber BiDi Modules Singlemode TX RX 1310 1550 10 km LC simplex DDM Support temp r 40 C 85...

Page 38: ...Bonnenbroicher Str 2 14 41238 Monchengladbach Germany Tel 49 2166 27 2220 Fax 49 2166 27 2499 Alsembergsesteenweg 2 b3 B 1501 Buizingen Belgium Tel 32 0 2 363 38 00 Fax 32 0 2 365 09 99 ...

Reviews: