Page 1: ...Fiber Optic Prism Switch USER S MANUAL...

Page 2: ...trument returned transportation prepaid Repaired products are warranted for the balance of the original warranty period or at least 90 days Limitation of Warranty This warranty does not apply to defec...

Page 3: ...ed for information only and product specifications are subject to change without notice Any change will be reflected in future printings 1999 Newport Corporation 1791 Deere Ave Irvine CA 92606 949 863...

Page 4: ...itions 1 2 1 3 2 Terminology 1 2 1 4 Product Overview 1 4 Section 2 Switch Control 2 1 2 1 Non Latching Two Pin Control 2 2 Section 3 Specifications 3 1 3 1 Housing Dimensions 3 2 Section 4 Handling F...

Page 5: ...2 Prism Switch 3 2 Figure 3 2 Housing Dimensions for 2x2 Prism Switch 3 3 Figure 4 1 Fiber Optic Component 4 2 List of Tables Table 2 1 Switch Control 2 1 Table 2 2 Switch Control 2 2 Table 3 1 Optica...

Page 6: ...vi Preface...

Page 7: ...oduct optical electrical environmental specifications and housing dimensions for the 1x2 and 2x2 Prism Switch Section 4 Handling Fiber Optic Components and Cables for the product are defined and also...

Page 8: ...only used terms found in the manual 1 3 1 Safety and General Symbols Definitions The following is a definition of safety and general symbol used in this manual ________________________________________...

Page 9: ...ed wavelength band Non Latching These style of switches require no power to maintain one position and a constant 5 VDC drive current to maintain the other position Polarization Dependent Loss PDL The...

Page 10: ...itches are actuated electrically and require 5 VDC to switch position The switches are housed in a compact environmentally stable package designed for mounting on printed circuit boards or within a mo...

Page 11: ...high signal depending on the switch position The position sensor is powered with 5 VDC on pin 3 Pins 1 2 and 3 are used for control and power supply Pin behavior depends upon the electrical configurat...

Page 12: ...VDC Low GND 5 VDC 5 VDC High Normal open contact Normal close contact Table 2 2 Switch Control 2 1 Non Latching Two Pin Control Switches configured for non latching two pin control require no power t...

Page 13: ...ut connectors Repeatability for 100 cycles at constant temperature Single mode only Measured at 1550 nm Table 3 1 Optical Specifications _______________________________________________________________...

Page 14: ...ble 3 3 Environmental Specifications 3 1 Housing Dimensions The following illustrations Figure 3 1 and Figure 3 2 show the Housing Dimensions for 1x2 and 2x2 Prism Switch Figure 3 1 Housing Dimensions...

Page 15: ...Prism Switch 10 1 25 6 7 2 2 54 TYP Pin 1 6 4 4 0 Aux Blind Mounting Hole M3X0 5 3 00 DP 2 Places 6 5 2 Places 4 0 6 0 16 0 Output 2 Output 1 3 3 7 8 11 4 20 0 40 0 61 0 26 0 3 3 Input 1 Input 2 32 0...

Page 16: ...3 4 Section 3 Specifications...

Page 17: ...ble strain relief boot Bending an optical cable near a strain relief boot is one of the easiest ways to permanently damage the optical fiber Avoid bending the optical cable over a sharp edge Avoid usi...

Page 18: ...ables have been connected Figure 4 1 Fiber Optic Component 4 2 Storing Optical Connectors All switches are shipped with dust caps in place covering all optical connectors Optical connectors should rem...

Page 19: ...ting process can permanently damage the connector Insert the appropriate connector ferrule into the adapter smoothly Do not allow the fiber tip to contact any surface If the tip accidentally contacts...

Page 20: ...bles Optical power trending slowly increasing or decreasing is caused by the slow evaporation of alcohol trapped in the connection Continue to monitor optical power until it stabilizes If the loss is...

Page 21: ...t com srvc service html Table 5 1 Technical Customer Support Contacts Contact Newport to obtain information about factory service Telephone contact number s are provided on the Service Form see next p...