EX
execute a program
IMM
PGM
MIPO
USAGE
♦
♦
SYNTAX
xx
EX
nn
PARAMETERS
Description
xx
[ int ] -
program number
nn
[ int ] -
number of times to execute the program
Range
xx
-
1
to
100
nn
-
1
to
2147385345
Units
xx
-
none
nn
-
none
Defaults
xx
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error 7, PARAMETER OUT OF RANGE
nn
missing:
1 assumed
out of range:
error 7, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to start executing a program. When the command is
received the controller executes the program line by line or according to the flow control
instructions.
During program execution, only commands that ask for information and that stop the
motion are still allowed. Any of the following commands will terminate a program, in
one way or another: AB, AP, MF, RS and ST. Most natural way to just stop a program
execution is by using the AP command, the other ones having a more drastic effect.
RETURNS
none
REL. COMMANDS
QP
-
quit programming mode
EP -
enter program mode
AP -
abort stored program execution
XX
-
erase program
EXAMPLE
3XX
|
clear program 3 from memory, if any
3EP
|
activate program mode and enter following commands as
|
program 3
•
•
•
QP
|
end entering program and quit programming mode
3EX
|
run stored program number 3
3-58
Section
3
–
Remote
Mode
Summary of Contents for ESP300 Series
Page 1: ...ESP300 Motion Controller Driver User s Manual...
Page 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Page 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Page 30: ......
Page 230: ...4 16 Section 4 Advanced Capabilities...
Page 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Page 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...