Page 1: ...Agilis D Controller with Strain Gages Feedback LabVIEW Driver Manual in NSTRUCT Environment V2 0 x CONEX AGAP For Motion Think Newport...

Page 2: ...CONEX AGAP Agilis D Controller with Strain Gages Feedback EDH0293En1020 09 12 Page ii...

Page 3: ...Driver 3 2 2 Adding Newport Instrument menu to LabVIEW 4 2 3 Menu Contents for Newport Instrument 5 3 0 LabVIEW Example with CONEX AGAP Instrument 7 3 1 LabVIEW Project Creation 7 3 2 First Step Inst...

Page 4: ...CONEX AGAP Agilis D Controller with Strain Gages Feedback EDH0293En1020 09 12 Page iv...

Page 5: ...AGAP uses the NET assembly named Newport ConexAGAP CommandInterface DLL The current Newport LabVIEW driver structure has been implemented following the National Instruments instructions on Loading NE...

Page 6: ...and play If the Newport instrument cannot be detected automatically open the NSTRUCT server to add this instrument to the server To do that refer you to the video How to add an instrument from NSTRUCT...

Page 7: ...files for each instrument in NSTRUCT Instruments folder From the selected instrument directory a LabVIEW directory contains the LabVIEW driver C Program Files Newport Instrument Manager NSTRUCT Instru...

Page 8: ...menu must be copied in the directory user lib of your LabVIEW This menu allows you to access to each instrument driver when the User libraries is selected from the LabVIEW functions panel For each in...

Page 9: ...s list Outputs ConexPSD Reference represents the instrument instance Component ID the identifier of the instrument from the NSTRUCT server error out contains LabVIEW error information LWConexPSD_Disco...

Page 10: ...e user to refer to the controller s manual to get the description of the command to select Inputs reference is the refnum associated with the instrument object on which you want to invoke a method or...

Page 11: ...done from this opened project 3 2 First Step Instrument Connection In your LabVIEW project open a new LabVIEW diagram right click to open the functions panel and choose the User libraries menu Next s...

Page 12: ...refers to the NSTRUCT server This ComponentID must be used with each subsequent function from the instrument instance 3 3 Second Step Invoking an Instrument Command Select the node of method from the...

Page 13: ...e After the link the node of method header becomes ConexAGP Now a list of functions for the selected instrument is accessible Right click on the node of method and select the menu select a method a li...

Page 14: ...tions panel and choose the User libraries menu Next go to the Instrument for NSTRUCT menu and select the LWInstrument_Disconnect vi For CONEX AGP the selected VI will be LWConexAGP_Disconnect vi from...

Page 15: ...CONEX AGAP Agilis D Controller with Strain Gages Feedback 3 5 2 Diagram 3 5 3 Associated front panel Page 11 EDH0293En1020 09 12...

Page 16: ...ers the project to be the running executable The CLR therefore searches for private assemblies in the project directory If you reference a NET assembly from a VI and the assembly does not belong to th...

Page 17: ...__________________________________________________________ ____________________________________________________________________________________________________________________ ________________________...

Page 18: ...Technical Support Tel 800 222 6440 e mail tech newport com Service RMAs Returns Tel 800 222 6440 e mail rma service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois Sauvage 91055...