30 

nlscan.com 

Industrial 2 of 5 

Read: 
Format 

Data digits (variable)  Check digit (optional) 

Max./Min. code length: Refer to Max./Min. code length of Code 39. 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
 

  SETUP 

Option bar code 

Option 

Alpha. entry 

Read 

 

Disable 
Enable 

00 
01* 

Max. code length 

 

00-99 
 

00-99 
00* 

Min. code length 

 

00-99 
 

00-99 
00* 

Code ID setting 

 

00-FF

16

   

(ASCII) 

00-FF

16

 

<H>* 

Insert group selection 

 

00-66 
 

00-66 
00* 

Reserved 

 

 

 

  END 

 

Summary of Contents for NLS-HR2180

Page 1: ...NLS HR2180 HR2280 High Performance Wireless Hand held 1D 2D Barcode Scanner User Guide HR2180_2280_UM_EN_V1 1 14...

Page 2: ...DC adaptor for battery charge and a CD ROM containing software and electrical manuals A 5V AC DC adaptor for RS 232 cable is optional 6 Do not throw or drop the scanner or otherwise subject it to str...

Page 3: ...fluid leakage heat emission explosion and fire Never dispose of the battery by incinerating it or otherwise expose it to heat Doing so creates the danger of battery heat emission explosion and fire N...

Page 4: ...ates the danger of electrical shock Abnormal conditions Should the unit become hot or start to emit smoke or a strange odor immediately turn off the power and contact your original dealer Continued us...

Page 5: ...yes do not rub them Immediately rinse your eyes with clean water such as tap water and then consult a physician immediately Cradle with RS 232 cable and adaptor Power the cradle only with a power outl...

Page 6: ...the danger of personal injury Should the mirror ever break never touch the mirror broken Doing so can cause personal injury Lithium ion battery Never leave the battery in an area expose to direct sun...

Page 7: ...plug while your hands are wet Doing so can create the danger of electrical shock Be sure to unplug the power cord from the wall outlet before moving the Basic Unit Failure to do so can result in dama...

Page 8: ...nstallation of cradle 7 RF communication as clusters 8 Scanning 9 Programming instruction 10 Keyboard wedge for Cradle 11 RS 232 interface for Cradle 13 USB interface for Cradle 15 Handheld scan some...

Page 9: ...43 China Finance 44 China Finance Continued 45 QR Code 46 Aztec 47 DataMatrix 48 HanXin Code 49 G1 G6 FN1 substitution string setting 50 G1 G4 string position Code ID position 53 String transmission 5...

Page 10: ...method Manual reading special barcode Program upgrade Using RSM software while a cradle unit is required Refer to RSM user manual Operating temperature 0 C to 50 C 32 F to 120 F Storage temperature 40...

Page 11: ...ecial barcode Program upgrade PC online using RSM software Refer to RSM user manual Operating temperature 0 to 50 C 32 to 120 F Storage temperature 40 to 60 C 40 to 140 F Humidity 5 to 95 non condensi...

Page 12: ...4 N Fm Code 128 1 K Cm Code 93 1 L Gm Code 11 4 V MSI Plessey 4 O Mm UK Plessey 1 U Mm UCC EAN 128 1 K Cm China Post 11 2 T Im China Finance 10 2 Y GS1 DataBar 16 2 R em GS1 DataBar 3 16 2 R em GS1 D...

Page 13: ...4 nlscan com Dimensions...

Page 14: ...r Communication Charge socket Power button Sound hole Red LED Not successful transmission Blue LED Power Green LED Setting Cradle B button Reserved S button Upgrade Reset P button USB Emulate Red LED...

Page 15: ...er off handheld unit Press the power button see Parts of the scanner for two seconds Charge battery 1 Please charge the battery before the first time of use The charge indicator red LED on the handhel...

Page 16: ...ug the output of the AC DC adaptor into the power terminal of on the cradle Plug the AC DC adaptor provided by the manufacturer into an electrical outlet 3 Windows gives message on new hardware found...

Page 17: ...ocol cordless scanner is able to pick up a higher performance RF channel from a group of channels in terms of consolidated communication LR 433 WPAN protocol supports up to 128 handheld units 16 handh...

Page 18: ...ning When the scanner is scanning programming codes in this manual ensure the scan line crosses the symbol as illustrated below to prevent scanning other nearby codes in its area HR2180 RIGHT WRONG HR...

Page 19: ...code listed on the lower right hand corner of each parameter setting part 5 Notes that only one parameter can be setup at each time 6 During the process of programming LED is lighting to indicate the...

Page 20: ...be specially adapted for use with different national keyboard layout Power on simulation All of the PCs check the keyboard status during power on self test It simulates keyboard timing and passes keyb...

Page 21: ...us 00 01 02 03 04 05 Delay after compound key 0ms 10ms 20ms 40ms 80ms 00 01 02 03 04 Numeric key Alphabetic key Numeric keypad Alt keypad 00 01 02 Power on simulation Disable Enable 00 01 Inter charac...

Page 22: ...igh RTS the scanner can be set to match the Serial Host RTS line XON XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character ACK NAK After transmitting da...

Page 23: ...t idle High RTS XON XOFF ACK NAK 00 01 02 03 04 Inter character delay 0ms 5ms 10ms 20ms 40ms 80ms 00 01 02 03 04 05 Reserved Response delay 00 99 100ms 00 99 00 Baud rate 300 600 1200 2400 4800 9600 1...

Page 24: ...to Host comm port speed of Keyboard wedge for Cradle Numeric key Refer to Numeric key of Keyboard wedge for Cradle SETUP Option bar code Option Alpha entry USB device type HID keyboard HID keyboard fo...

Page 25: ...e decoded data to confirm a valid reading Global Max Min code length These two lengths are defined as the valid range of decoded barcode data length Make sure that the minimum length setting is no gre...

Page 26: ...ng mode Good read off Momentary Alternate Continue Timeout off 00 01 02 03 04 Standby duration 01 99 second 01 99 04 Same barcode delay time 00 FF16 50ms 00 FF16 08 Double confirm 00 09 00 no 00 09 00...

Page 27: ...anner will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favorite usage Example Visual and...

Page 28: ...when a user holding the handheld unit walks back into range Standard batch The handheld unit starts storing barcode data after EBM Enter Batch Mode is scanned Data transmission is triggered by scanni...

Page 29: ...8 01 08 06 Handheld unit ID 01 16 01 16 01 RF power level 10dbm 7dbm 5dbm 0dbm 5dbm 10dbm 15dbm 01 02 03 04 05 06 07 Frequency hopping Disable Enable 00 01 RF operating mode Normal Out of range batch...

Page 30: ...eld unit IDs are offered Example 1 to set a cradle to work on channel 2 and to bind the first handheld unit ID as 15 Steps Scan the following barcodes in order Example 2 to set a cradle to work on cha...

Page 31: ...F power level 10dbm 7dbm 5dbm 0dbm 5dbm 10dbm 15dbm 01 02 03 04 05 06 07 Frequency hopping Disable Enable 00 01 END Show channel information of Cradle Note The settings indicated with are valid only w...

Page 32: ...plement digits The Supplement digits barcode is the supplemental 2 or 5 characters Format Leading zero Data digits 11 digits Check digit Supplement digits 2 or 5 Truncation Expansion Truncate leading...

Page 33: ...xpansion Truncate leading zeros Refer to Truncation Expansion of UPC A Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is set to be enabled Example Barcode 0123654 Output 00123...

Page 34: ...International Standard Book Number and ISSN International Standard Serial Number are two kinds of barcode for books and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with l...

Page 35: ...p selection of UPC A Supplement digits Format Data digits 7 digits Check digit Supplement Digits 2 or 5 Truncation Expansion Refer to Truncation Expansion of UPC A SETUP Option bar code Option Alpha e...

Page 36: ...gth barcode decoded Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Start End transmission The start and end characters of Code...

Page 37: ...ode length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format Standard Full ASCII 00 01 Start End transmission Disable Enable 00 01 as data character D...

Page 38: ...mission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer...

Page 39: ...39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Max code l...

Page 40: ...e length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Al...

Page 41: ...d pattern you may select one pair to match your application Start End transmission Refer to Start End transmission of Code 39 Start End character equality By setting Enable the start and end character...

Page 42: ...n group selection Refer to Insertion group selection of UPC A Truncate leading zeros The leading 0 digits of Code 128 barcode characters can be truncated when the feature is enabled SETUP Option bar c...

Page 43: ...length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alp...

Page 44: ...ion method Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Opt...

Page 45: ...git 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of U...

Page 46: ...t will be transmitted Max Min code length Refer to Max Min code length of Code 39 Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC...

Page 47: ...ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Truncate leading zeros Refer to Truncate leading zeros of Code 128 SETUP Option bar code Option Alpha entry Re...

Page 48: ...D setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Reserved Reserved Reserved Reserved Code ID...

Page 49: ...selection of UPC A Conversion UCC EAN 128 Refer to Code ID transmission of String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit h...

Page 50: ...ection Refer to Insertion group selection of UPC A Conversion Refer to Conversion of GS1 DataBar GS1 DataBar Truncated SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Code ID settin...

Page 51: ...ction of UPC A Conversion UCC EAN 128 Refer to Code ID transmission of String transmission Cm will be identified as AIM ID SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Max code l...

Page 52: ...r correction level for a PDF417 symbol is from 0 to 8 This scanner can only support the levels from 0 to 6 Read Format Data characters variable Code ID setting Refer to Code ID setting of UPC A Insert...

Page 53: ...Min code length Refer to Max Min code length of Code 39 Check digit verification The check digit is made as the sum module 10 of the numerical values of all data digits Leading character 5 6 7 8 9 co...

Page 54: ...ed to E 00 01 02 03 04 05 06 Leading character assignment Disable Assigned to 0 Assigned to 5 A Assigned to 6 B Assigned to 7 C Assigned to 8 D Assigned to 9 E Assigned to 1 Assigned to 2 Assigned to...

Page 55: ...R2280 model only Read Format Data characters variable Code ID setting Refer to Code ID setting of UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 00 01 Code ID setting 00 FF16 ASCII...

Page 56: ...aracters variable Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alpha entry Read Disable Enable 0...

Page 57: ...characters variable Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alpha entry Read Disable Enable...

Page 58: ...characters variable Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A SETUP Option bar code Option Alpha entry Read Disable Enabl...

Page 59: ...l of as a prefix for all symbologies Steps 1 Scan SETUP and Prefix string setting barcode 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the foldout back page 4 Scan...

Page 60: ...mber is more than the barcode data characters The option of FF for this setting is not active while the option of Truncate leading G5 string setting is 00 Example Truncate all leading zeros for all sy...

Page 61: ...2 string setting 0 22 characters None 00 FF16 00 Insert G3 string setting 0 22 characters None 00 FF16 00 Insert G4 string setting 0 22 characters None 00 FF16 00 FN1 substitution string setting 0 4 c...

Page 62: ...se of the insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement SETUP O...

Page 63: ...ither Proprietary ID or AIM ID Refer to the chapter of Default setting for each barcode Code length transmission The length of code data string can be transmitted before the code data when Enable is s...

Page 64: ...amble transmission Disable Enable 00 01 Postamble transmission Disable Enable 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Case conve...

Page 65: ...56 nlscan com Test Chart UPC A UPC E EAN 8 EAN 13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Code 93 UCC EAN 128 Code 11...

Page 66: ...57 nlscan com Test Chart Continued MSI Plessey UK Plessey ISBN ISSN China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Expanded PDF417 01Az MicroPDF417 23 mdo...

Page 67: ...58 nlscan com Test Chart Continued QR Code 0123456789 Aztec 01AZ za98 DataMatrix 0123456789 Hanxin Code...

Page 68: ...it is not defaced Try scanning test symbols of the same bar code type Scanner is not programmed for the correct bar code type Be sure the scanner is programmed to read the type of bar code you are sc...

Page 69: ...affect scanning accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not spray wat...

Page 70: ...Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge...

Page 71: ...to the entire factory default settings radio communication setting is not included scan the barcode above Note This setting is valid only when the cradle is in upgrade ready mode Refer to chapter of R...

Page 72: ...63 nlscan com Configuration alphanumeric entry barcode...

Page 73: ...aPac Office Newland Taiwan Co Ltd 7F 6 No 268 Liancheng Rd Zhonghe City Taipei County Taiwan TEL 886 2 77315388 WEB www newland id com EMEA office Newland Europe BV Nijverheidsweg 1 d e 6651 KS Druten...