Getting Start
nlscan.com
Page 23
Code Programming ON
Code Programming OFF
Tools
“
Send Sys Info
”
, the engine sends system information to the Host immediately.
“
Power ON, Send Sys Info
”
, the engine sends system information to the Host right after Power
ON.
Send Sys Info
【
Pro CMD
:
0003000
】
System Information
Title
Remarks
Dev
device type
Ver
BIOS version
Date
BIOS version establishing time
S/N
device serial number
ESN
user-defined device serial number
Interface
3 types of communication interfaces:
USB, append narration could be HID-KBW, DataPipe, Virtual RS232.
1.
RS232, append narration could be baud rate, parity check byte, data bit and stop bit, in the
2.
order.
PS/2, no append narration
3.
1D
Indicate that reading 1D is allowed. Symbologies are divided by comma. Appended information:
1.
“
+
”
affiliate features
2. Min Message Length -> Max Message Length
3.
“
No Check Digit
”
for do parity check
,
“
Check Digit
”
for the contrary
4.
“
Fixed Length: 2~64 even value
”
. It is in this format: Fixed Length: 2 4 6 8 10 12...
2D
Indicate that reading 1D is allowed. Symbologies are divided by comma. Appended information:
Min Message Length -> Max Message Length
Scan Mode
1. Manual Scan =
“
Hand-held Mode
”
in this book
2. Auto Scan =
“
Continuous Mode
”
in this book
3. Induced Scan =
“
Sensor Mode
”
in this book
The system information is provided in such format
Title: contents (append narration 1, narration 2)
Power ON, Send Sys Info
【
Pro CMD
:
0007010
】
** Power ON, Not Send Sys Info
【
Pro CMD
:
0007000
】