nlscan.com
Page 80
Symbols
Code Programming ON
Code Programming OFF
Tools
Codabar
Select Message Length
It is used to program the valid reading length of Codabar. The engine will not
send barcode message to the Host, if the decoded data length does not match
the valid length.
Codabar Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max. Message Length
“
.
Min Message Length (default: 2)
【
Pro CMD
:
0409030
】
Max Message Length (default: 60)
【
Pro CMD
:
0409040
】
1D bar code Message Length should not exceed 127 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.