background image

 

                                                                                                                                                                                 

Enter Setup

 

 

89                                                                                                                                                                                    *

* Exit Setup

 

 

Standard 2 of 5

IATA 2 of 5

 

Restore Factory Defaults 

 

 

Restore the Factory Defaults of Standard 25

 

 

 

 

 

Enable/Disable Standard 25 

 

 

 

**

 Enable Standard 25

 

 

Disable Standard 25

 

 

 

 

 

Set Length Range for Standard 25 

 

 

 

Set the Minimum Length

 

 

Set the Maximum Length

 

 

Summary of Contents for NLS-FM3051-2X

Page 1: ...NLS FM305X 2X Fixed Mount Barcode Scanner User Guide...

Page 2: ...tion or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujian New...

Page 3: ...lease July 27 2017 V1 0 1 Added the Enable Disable PDF417 ECI Output Enable Disable QR ECI Output and Enable Disable Data Matrix ECI Output features in Chapter 8 Note Firmware version V1 00 088 or lat...

Page 4: ......

Page 5: ...g the FM30 to a Host Device 8 Using USB Cable 9 Using RS 232 Cable 10 Maintenance 11 Scanning Instructions 11 Barcode Programming 12 Factory Defaults 13 Custom Defaults 13 Query Product Information 13...

Page 6: ...on Timeout 31 Image Stabilization Timeout 32 Timeout between Decodes 32 Timeout between Decodes Same Barcode 33 Sensitivity 34 Continuous Mode 35 Decode Session Timeout 35 Timeout between Decodes 35 T...

Page 7: ...stom Suffix 52 Set Custom Suffix 52 Terminating Character Suffix 53 Enable Disable Terminating Character Suffix 53 Set Terminating Character Suffix 54 Chapter 8 Symbologies 55 Global Settings 55 Enabl...

Page 8: ...13 Beginning with 414 419 Add On Code Required 66 EAN 13 Beginning with 434 439 Add On Code Required 66 EAN 13 Beginning with 977 Add On Code Required 67 EAN 13 Beginning with 978 Add On Code Required...

Page 9: ...Defaults 85 Enable Disable Matrix 2 of 5 85 Set Length Range for Matrix 2 of 5 85 Check Character Verification 86 Industrial 2 of 5 87 Restore Factory Defaults 87 Enable Disable Industrial 2 of 5 87...

Page 10: ...ication 99 GS1 Databar RSS 100 Restore Factory Defaults 100 Enable Disable GS1 Databar 100 Transmit Application Identifier 01 100 Code 11 101 Restore Factory Defaults 101 Enable Disable Code 11 101 Se...

Page 11: ...Disable Data Matrix 113 Set Length Range for Data Matrix 113 Rectangular Barcode 114 Data Matrix Twin Code 114 Character Encoding 115 Enable Disable Data Matrix ECI Output 115 Chinese Sensible Code 1...

Page 12: ...ween Decodes Same Barcode 160 d Program the Threshold Value of Illumination Change 161 e Program the Timeout between Decodes 161 f Program the Decoding Area 162 g Program the Custom Prefix Suffix 162...

Page 13: ...Appendix 9 Code Pages List 172 Appendix 10 Symbology ID Number 173...

Page 14: ......

Page 15: ...is scanner is easy to fit into various equipment such as self service cabinets vending machines ATMs access control retail POS and fast food self ordering kiosks About This Guide This guide provides p...

Page 16: ...51 2X FM3056 2X Data Port Pinout PIN Signal Type Function 1 NC NC 2 NC NC 3 VCC P Power DC5V 4 TXD O RS 232 output 5 RXD I RS 232 input 6 CTS I O Clear to send RS 232 7 RTS I O Request to send RS 232...

Page 17: ...Enter Setup 3 Exit Setup Dimensions unit mm FM3056 2X Scanner...

Page 18: ...Enter Setup Exit Setup 4 FM3051 2X Scanner...

Page 19: ...Enter Setup 5 Exit Setup IR Triggering Range...

Page 20: ...Enter Setup Exit Setup 6 Optics Horizontal...

Page 21: ...Enter Setup 7 Exit Setup Vertical...

Page 22: ...ted to a host device in actual application such as PC POS or any intelligent terminal with USB or RS 232 port using a USB or RS 232 cable USB USB port on the host device RS 232 RS 232 port on the host...

Page 23: ...USB Cable Connect the scanner to a host device with a USB cable with RJ45 and USB connectors 1 Plug the cable s RJ45 connector into the data port on the scanner 2 Plug the cable s USB connector into t...

Page 24: ...cable with RJ45 RS 232 connector and a power jack 1 Plug the cable s RJ45 connector into the data port on the scanner 2 Plug the cable s RS 232 connector into the RS 232 port on the host device 3 Plug...

Page 25: ...Do not spray any liquid on the scan window Do not use any detergent to clean other parts of the device except for water Note The warranty DOES NOT cover damages caused by inappropriate care and mainte...

Page 26: ...odes such as the Enter Setup barcode and Restore All Factory Defaults barcode can be read Enter Setup Exit Setup Programming barcode data i e the characters under programming barcode can be transmitte...

Page 27: ...an save the current settings as custom defaults Once custom default settings are stored they can be recovered at any time by scanning the Restore All Custom Defaults barcode Custom defaults are stored...

Page 28: ...the interface RS 232 Interface When the scanner is connected to the RS 232 port of a host device the scanner will automatically enable RS 232 communication However you need to set communication param...

Page 29: ...Enter Setup 15 Exit Setup Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the Host requirements 9600 1200 19200 2400 38400 4800 57600 14400 115200...

Page 30: ...to 7 you can only select either Even Parity or Odd Parity The None option will be regarded as Even Parity in this case None Even Parity Odd Parity Data Bits When the number of data bits is set to 7 yo...

Page 31: ...Enter Setup 17 Exit Setup Stop Bits 1 Stop Bit 2 Stop Bits...

Page 32: ...vice via a USB connection you can enable the USB HID KBW feature by scanning the barcode below Then scanner s transmission will be simulated as USB keyboard input The host device receives keystrokes o...

Page 33: ...Enter Setup 19 Exit Setup USB Country Keyboard Types Keyboard layouts vary from country to country The default setting is U S keyboard U S Belgium Brazil Canada Czechoslovakia Denmark Finland France...

Page 34: ...Enter Setup Exit Setup 20 Germany Austria Greece Hungary Israel Italy Latin America South America Netherlands Norway Poland Portugal...

Page 35: ...Setup Romania Russia Slovakia Spain Sweden Switzerland Turkey_F Turkey_Q UK Japan Note To program the scanner to get proper output for Russian encoded with Windows 1251 or UTF 8 PDF417 QR Code Data Ma...

Page 36: ...mit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when an unknown character is detected Beep on Unknown Character Do Not Beep on Unknown Character...

Page 37: ...he appropriate barcode below to convert barcode data to your desired case No Case Conversion Convert All to Upper Case Convert All to Lower Case Example When the Convert All to Lower Case feature is e...

Page 38: ...ed keyboard type but falling into 0x20 0xFF are sent in the ALT Keypad way Mode 2 ASCII characters falling into 0x20 0xFF are sent in the ALT Keypad way Mode 3 ASCII characters falling into 0x00 0xFF...

Page 39: ...tion characters 0x00 0x1F are sent as ASCII sequences over the keypad For more information see Appendix 8 ASCII Function Key Mapping Table Example Barcode data 0x16 Enable Function Key Mapping Ctrl V...

Page 40: ...ber 0 9 is emulated as keystroke s on numeric keypad whereas sending other characters like and is still emulated as keystrokes on main keyboard Do Not Emulate Numeric Keypad Emulate Numeric Keypad Cod...

Page 41: ...Setup 27 Exit Setup Polling Rate This parameter specifies the polling rate for a USB keyboard If the Host drops characters change the polling rate to a bigger value 1ms 2ms 3ms 4ms 5ms 6ms 7ms 8ms 9ms...

Page 42: ...interface is recommended for new application programs It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation Features HID based no custom driver requ...

Page 43: ...erfaces go to www USB org Acquire Scanned Data After scanning and decoding a barcode the scanner sends the following input report Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x02 1 Length of the barcode 2 57...

Page 44: ...uct ID to identify and locate a device The VID is assigned by USB Implementers Forum Newland s vendor ID is 1EAB Hex A PID is assigned to each interface Product Interface PID Hex PID Dec FM30 USB HID...

Page 45: ...session continues until the barcode is decoded or the decode session timeout expires Sense Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attem...

Page 46: ...s The default setting is 100ms To learn how to program this parameter see Appendix 5 Timeout between Decodes This parameter sets the timeout between decode sessions When a decode session ends next ses...

Page 47: ...the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Same Barcode Allow the scanner to re read same barcode Disable Timeout betw...

Page 48: ...itivity Threshold value 8 Low Sensitivity Threshold value 14 High Sensitivity Threshold value 5 Enhanced Sensitivity Threshold value 2 If the above four options fail to meet your needs you may program...

Page 49: ...s to 3 600 000ms When it is set to 0 the timeout is infinite The default setting is 3 000ms To learn how to program this parameter see Appendix 5 Decode Session Timeout Timeout between Decodes This pa...

Page 50: ...the scanner to re read same barcode before the timeout between decodes same barcode expires Disable Timeout between Decodes Same Barcode Allow the scanner to re read same barcode Disable Timeout betw...

Page 51: ...its field of view from the center to the periphery and transmits the barcode that has been first decoded Whole Area Decoding Specific Area Decoding The scanner attempts to read barcode s within a spec...

Page 52: ...white box is the decoding area Since Barcode 1 passes through the decoding area it will be read Barcode 2 does not pass through the decoding area so it will not be read You can define the decoding ar...

Page 53: ...Enter Setup 39 Exit Setup Top of Decoding Area Bottom of Decoding Area Left of Decoding Area Right of Decoding Area...

Page 54: ...ation options are provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on during image capture Always ON Illumination LEDs keep ON after the scann...

Page 55: ...ogrammed to beep when it is powered on Scan the Off barcode if you do not want a power on beep On Off Good Read Beep Scan the appropriate barcode below to enable or disable the emission of beep when a...

Page 56: ...Enter Setup Exit Setup 42 Beep Type Type 1 Type 3 Type 2 Beep Volume Loud Low Medium...

Page 57: ...y be unavailable on the selected keyboard USB HID KBW As a result the scanner fails to transmit the unknown characters Scan the appropriate barcode below to enable or disable the emission of beep when...

Page 58: ...ssage when a barcode cannot be decoded Bad Read Message ON Bad Read Message OFF To set a bad read message scan the Set Bad Read Message barcode and the numeric barcodes corresponding to the ASCII hex...

Page 59: ...can also be the alternatives Data editing may include Append AIM ID Code ID custom prefix before the decoded data Append custom suffix after the decoded data Append terminating character to the end of...

Page 60: ...ta with no prefix suffix Enable All Prefixes Suffixes Allow user to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission Enabl...

Page 61: ...ble Custom Prefix Set Custom Prefix To set a custom prefix scan the Set Custom Prefix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Page 62: ...er will add the symbology identifier before the scanned data after decoding Enable AIM ID Prefix Disable AIM ID Prefix Code ID Prefix Code ID can also be used to identify barcode type Unlike AIM ID Co...

Page 63: ...of a desired Code ID and then scan the Save barcode Refer to Appendix 4 ASCII Table for hexadecimal values of characters To view a setting example see Appendix 5 Parameter Programming Examples Modify...

Page 64: ...Modify EAN 13 Code ID Modify UPC E Code ID Modify UPC A Code ID Modify ISBN Code ID Modify ISSN Code ID Modify Code 39 Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify ITF 14 Co...

Page 65: ...Exit Setup Modify Codabar Code ID Modify Industrial 25 Code ID Modify Standard 25 Code ID Modify Matrix 25 Code ID Modify Code 11 Code ID Modify Plessey Code ID Modify MSI Plessey Code ID Modify GS1 D...

Page 66: ...ble Custom Suffix Set Custom Suffix To set a custom suffix scan the Set Custom Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired prefix and then scan the Save b...

Page 67: ...of data which means nothing can be added after it A terminating character suffix can contain 1 7 characters Enable Disable Terminating Character Suffix To enable disable terminating character suffix s...

Page 68: ...LF 0x0D 0x0A To set a terminating character suffix scan the Set Terminating Character Suffix barcode and the numeric barcodes representing the hexadecimal value s of a desired terminating character an...

Page 69: ...programming barcodes Enable All Symbologies Disable All Symbologies Enable Disable 1D Symbologies If the Disable 1D Symbologies feature is enabled the scanner will not be able to read any 1D barcodes...

Page 70: ...rcode and inverse barcode are shown below Regular Barcode Inverse Barcode Video Reverse allows the scanner to read barcodes that are inverted Video Reverse ON Read both regular barcodes and inverse ba...

Page 71: ...p 1D Symbologies Code 128 Restore Factory Defaults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 Set Length Range for Code 128 Set the Minimum Lengt...

Page 72: ...up 58 GS1 128 UCC EAN 128 Restore Factory Defaults Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128 Set Length Range for GS1 128 Set the Minimum Length Set...

Page 73: ...Exit Setup AIM 128 Restore Factory Defaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 Set Length Range for AIM 128 Set the Minimum Length Set the M...

Page 74: ...ory Defaults of EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Transmit Check Character EAN 8 is 8 digits in length with the last one as its check character used to verify the integrity of the...

Page 75: ...e Enable 2 Digit Add On Code Disable 2 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN 8...

Page 76: ...tup Exit Setup 62 Add On Code Required When EAN 8 Add On Code Required is selected the scanner will only read EAN 8 barcodes that contain add on codes EAN 8 Add On Code Required EAN 8 Add On Code Not...

Page 77: ...tup EAN 13 Restore Factory Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Transmit Check Character Transmit EAN 13 Check Character Do Not Transmit E...

Page 78: ...e scanner decodes a mix of EAN 13 barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code...

Page 79: ...on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 378 379 Add On Code Required This setting programs the scanner to require an...

Page 80: ...depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 434 439 Add On Code Required This setting programs the scanner to...

Page 81: ...depending on your selection for the Add On Code Required feature Do Not Require Add On Code Require Add On Code EAN 13 Beginning with 978 Add On Code Required This setting programs the scanner to req...

Page 82: ...that begin with 979 must have a 2 digit or 5 digit add on code The EAN 13 barcode with the add on code is then transmitted If the required add on code is not found the EAN 13 barcode is discarded Do N...

Page 83: ...Enter Setup 69 Exit Setup ISSN Restore Factory Defaults Restore the Factory Defaults of ISSN Enable Disable ISSN Enable ISSN Disable ISSN...

Page 84: ...Code The scanner decodes a mix of ISSN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISSN and ignores the add on co...

Page 85: ...Enter Setup 71 Exit Setup ISBN Restore Factory Default Restore the Factory Defaults of ISBN Enable Disable ISBN Enable ISBN Disable ISBN Set ISBN Format ISBN 13 ISBN 10...

Page 86: ...Code The scanner decodes a mix of ISBN barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes ISBN and ignores the add on co...

Page 87: ...t Setup UPC E Restore Factory Defaults Restore the Factory Defaults of UPC E Enable Disable UPC E Enable UPC E Disable UPC E Transmit Check Character Transmit UPC E Check Character Do Not Transmit UPC...

Page 88: ...The scanner decodes a mix of UPC E barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code...

Page 89: ...Enter Setup 75 Exit Setup Transmit System Character The first character of UPC E barcode is the system character 0 Transmit System Character Do Not Transmit System Character...

Page 90: ...etup 76 UPC A Restore Factory Defaults Restore the Factory Defaults of UPC A Enable Disable UPC A Enable UPC A Disable UPC A Transmit Check Character Transmit UPC A Check Character Do Not Transmit UPC...

Page 91: ...The scanner decodes a mix of UPC A barcodes with and without 2 digit 5 digit add on codes Disable 2 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code...

Page 92: ...and System Character can be transmitted as part of a UPC A barcode Select one of the following options for transmitting UPC A preamble to the host device transmit system character only or transmit sys...

Page 93: ...store Factory Defaults Restore the Factory Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Length Range for Interleaved 2 of 5...

Page 94: ...2 of 5 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted except the last digit whereas those failing it will not be transmitte...

Page 95: ...re is available only when USB HID KBW is enabled Transmit Delay per Character applies to both Expanded and Unexpanded Febraban while Transmit Delay per 12 Characters applies to Expanded Febraban only...

Page 96: ...ay per Character Transmit Delay per 12 Characters Set the transmit delay per 12 characters by scanning the appropriate barcode below according to your actual needs Set Transmit Delay per 12 Characters...

Page 97: ...of 14 characters and the last character as the check character Restore the Factory Defaults of ITF 14 Disable ITF 14 Enable ITF 14 But Do Not Transmit Check Character Enable ITF 14 and Transmit Check...

Page 98: ...th of 6 characters and the last character as the check character Restore the Factory Defaults of ITF 6 Disable ITF 6 Enable ITF 6 But Do Not Transmit Check Character Enable ITF 6 and Transmit Check Ch...

Page 99: ...2 of 5 Restore Factory Defaults Restore the Factory Defaults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set Length Range for Matrix 2 of 5 Set the Minimu...

Page 100: ...Enter Setup Exit Setup 86 Check Character Verification Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification...

Page 101: ...Restore Factory Defaults Restore the Factory Defaults of Industrial 2 of 5 Enable Disable Industrial 2 of 5 Enable Industrial 2 of 5 Disable Industrial 2 of 5 Set Length Range for Industrial 2 of 5 Se...

Page 102: ...Enter Setup Exit Setup 88 Check Character Verification Disable Transmit Check Character After Verification Do Not Transmit Check Character After Verification...

Page 103: ...2 of 5 IATA 2 of 5 Restore Factory Defaults Restore the Factory Defaults of Standard 25 Enable Disable Standard 25 Enable Standard 25 Disable Standard 25 Set Length Range for Standard 25 Set the Mini...

Page 104: ...Enter Setup Exit Setup 90 Check Character Verification Disable Transmit Check Character After Verification Do Not Transmit Check Character After Verification...

Page 105: ...Code 39 Restore Factory Defaults Restore the Factory Defaults of Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do Not Trans...

Page 106: ...cter Verification Disable Transmit Check Character After Verification Do Not Transmit Check Character After Verification Enable Disable Code 39 Full ASCII The scanner can be configured to identify all...

Page 107: ...le Code 32 Code 39 must be enabled and Code 39 check character verification must be disabled for this parameter to function Disable Code 32 Enable Code 32 Code 32 Prefix Scan the appropriate barcode b...

Page 108: ...d for this parameter to function Do Not Transmit Code 32 Check Character Transmit Code 32 Check Character Transmit Code 32 Start Stop Character Code 32 must be enabled for this parameter to function D...

Page 109: ...Exit Setup Codabar Restore Factory Defaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar Set Length Range for Codabar Set the Minimum Length Set the M...

Page 110: ...heck Character Verification Disable Transmit Check Character After Verification Do Not Transmit Check Character After Verification Transmit Start Stop Character Transmit Start Stop Character Do Not Tr...

Page 111: ...ormat You can choose your desired start stop character format by scanning the appropriate barcode below ABCD ABCD as the Start Stop Character ABCD TN E as the Start Stop Character Start Stop Character...

Page 112: ...it Setup 98 Code 93 Restore Factory Defaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 Set Length Range for Code 93 Set the Minimum Length Set the M...

Page 113: ...Enter Setup 99 Exit Setup Check Character Verification Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification...

Page 114: ...store Factory Defaults Restore the Factory Defaults of GS1 Databar Enable Disable GS1 Databar Enable GS1 DataBar Disable GS1 DataBar Transmit Application Identifier 01 Transmit Application Identifier...

Page 115: ...1 Exit Setup Code 11 Restore Factory Defaults Restore the Factory Defaults of Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Set Length Range for Code 11 Set the Minimum Length Set the...

Page 116: ...t Check Character Check Character Verification Disable One Check Character MOD11 Two Check Characters MOD11 MOD11 Two Check Characters MOD11 MOD9 One Check Character MOD11 Len 10 Two Check Characters...

Page 117: ...3 Exit Setup Plessey Restore Factory Defaults Restore the Factory Defaults of Plessey Enable Disable Plessey Enable Plessey Disable Plessey Set Length Range for Plessey Set the Minimum Length Set the...

Page 118: ...Enter Setup Exit Setup 104 Check Character Verification Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification...

Page 119: ...MSI Plessey Restore Factory Defaults Restore the Factory Defaults of MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Set Length Range for MSI Plessey Set the Minimum Len...

Page 120: ...tup 106 Transmit Check Character Transmit Check Character Do Not Transmit Check Character Check Character Verification Disable One Check Character MOD10 Two Check Characters MOD10 MOD10 Two Check Char...

Page 121: ...t Setup 2D Symbologies PDF417 Restore Factory Defaults Restore the Factory Defaults of PDF417 Enable Disable PDF417 Enable PDF417 Disable PDF417 Set Length Range for PDF417 Set the Minimum Length Set...

Page 122: ...pecifications and be placed closely together There are 3 options for reading PDF417 twin codes Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes Both Single Twin Read...

Page 123: ...Enter Setup 109 Exit Setup Enable Disable PDF417 ECI Output Disable PDF417 ECI Output Enable PDF417 ECI Output...

Page 124: ...Restore Factory Defaults Restore the Factory Defaults of QR Code Enable Disable QR Code Enable QR Code Disable QR Code Set Length Range for QR Code Set the Minimum Length Set the Maximum Length Micro...

Page 125: ...ave similar specifications and be placed closely together There are 3 options for reading QR twin codes Single QR Only Read either QR code Twin QR Only Read both QR codes Both Single Twin Read both QR...

Page 126: ...Enter Setup Exit Setup 112 Enable Disable QR ECI Output Disable QR ECI Output Enable QR ECI Output...

Page 127: ...Data Matrix Restore Factory Defaults Restore the Factory Defaults of Data Matrix Enable Disable Data Matrix Enable Data Matrix Disable Data Matrix Set Length Range for Data Matrix Set the Minimum Len...

Page 128: ...be placed closely together There are 3 options for reading Data Matrix twin codes Single Data Matrix Only Read either Data Matrix code Twin Data Matrix Only Read both Data Matrix codes Transmission o...

Page 129: ...Enter Setup 115 Exit Setup Character Encoding Default Character Encoding UTF 8 Enable Disable Data Matrix ECI Output Disable Data Matrix ECI Output Enable Data Matrix ECI Output...

Page 130: ...Factory Defaults Restore the Factory Defaults of Chinese Sensible Code Enable Disable Chinese Sensible Code Enable Chinese Sensible Code Disable Chinese Sensible Code Set Length Range for Chinese Sen...

Page 131: ...mage captured by the scanner to meet actual need by scanning the appropriate barcode on the next page The following figures illustrate original image and three flipped images Original Image Image Flip...

Page 132: ...Enter Setup Exit Setup 118 Do Not Flip Flip Vertically Flip Horizontally Flip Horizontally and Vertically...

Page 133: ...ed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Default Data Format Add a Data Format Data format is used to edit barco...

Page 134: ...ID number of the symbology to which you want to apply the data format Scan three numeric barcodes for the symbology ID number If you wish to create a data format for all symbologies scan 999 Step 7 S...

Page 135: ...0 characters applicable send all characters followed by A 1 Scan the Enter Setup barcode Enter the Setup mode 2 Scan the Add Data Format barcode Add a data format 3 Scan the 0 barcode Select format_0...

Page 136: ...ingly and gets outputted without prefixes and suffixes even if prefix and suffix are enabled Any data that does not match your data format requirements generates an error beep if Non Match Error Beep...

Page 137: ...Enable Data Formatter Not Required Keep Prefix Suffix Enable Data Formatter Not Required Drop Prefix Suffix Non Match Error Beep If Non Match Error Beep is turned ON the scanner generates an error bee...

Page 138: ...ing the data format selected here then reverts to the format you have selected above For example you may have set your scanner to the data format you saved as Format_3 You can switch to Format_1 for a...

Page 139: ...Save barcode Delete all data formats Scan the Clear All barcode Clear All Clear One Query Data Formats You may scan the appropriate barcode below to get the information of data format s created by yo...

Page 140: ...age starting from current cursor position followed by an insert character F2 Send a number of characters Syntax F2nnxx nn The numeric value 00 99 for the number of characters xx The insert character s...

Page 141: ...return Command string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR E9 Send...

Page 142: ...nd to ignore F4 is the Insert a character multiple times command 09 is the hex value for a horizontal tab 02 is the number of times the tab character is sent The data is output as 1234567890AB tab tab...

Page 143: ...ce 01 is the number of time the space character is sent B4 is the Insert barcode length command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of...

Page 144: ...cursor F1 is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move the cursor backward a number of characters Syntax F6nn nn The numeric valu...

Page 145: ...Search for the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is the Search forward for a character command 44 is the hex v...

Page 146: ...data that follows including FGH Using the barcode above Command string B00003464748F10D B0 is the Search forward for a string command 0003 is the string length 3 characters 46 is the hex value for F...

Page 147: ...ll the data that follows E6 searches forward for the first character that is not zero then sends all the data after followed by a carriage return Using the barcode above Command string E630F10D E6 is...

Page 148: ...rent cursor position as the cursor is advanced by other commands FB Example Remove spaces in barcode data This example shows a barcode that has spaces in the data You may want to remove the spaces bef...

Page 149: ...e has characters that the host application does not want included you can use the E4 command to replace those characters with something else In this example you will replace the zeros in the barcode a...

Page 150: ...nt cursor position search forward for the occurrence of SS1 string of length NN1 and replace the string with SS2 string of length NN2 in the output message until every SS1 string is replaced or the co...

Page 151: ...23 s in barcode data If the barcode has a string of characters that the host application wants removed you can use the BA command to replace the string with NUL In this example you will remove the fir...

Page 152: ...between the 5th and 6th character Send the first 5 characters in a barcode wait for 1s then send the rest of the barcode data Command string F20500EF0200E900 F2 is the Send a number of characters com...

Page 153: ...a semicolon Note that there is no space between a command and its terminator semicolon 3 Use the barcode generator software to generate a 2D batch barcode Example Create a batch barcode for Illuminati...

Page 154: ...or more information refer to the Serial Programming Command Manual Create a Batch Barcode Batch barcodes can be produced in the format of PDF417 QR Code or Data Matrix Example Create a batch barcode f...

Page 155: ...Enter Setup 141 Exit Setup Use Batch Barcode To put a batch barcode into use scan the following barcodes Use the example above Enter Setup Enable Batch Barcode Batch Barcode Exit Setup...

Page 156: ...olution 1 If this problem happens to all barcodes and additional characters appear before after barcode data disable all prefix suffix 2 If this problem only happens to some barcodes and matches one o...

Page 157: ...t the scanner is properly powered up 2 Send to the scanner If the scanner returns a reply of then send programming commands to turn illumination on Problem Carriage Return Line Feed settings Solution...

Page 158: ...ettings RS 232 Baud Rate 115200 Parity Check None Data Bits 8 Stop Bits 1 HID KBW USB Country Keyboard Type U S Beep on Unknown Character Do not beep Inter Keystroke Delay 10ms Convert Case No convers...

Page 159: ...o Sense mode and Continuous mode 0 65 535ms Threshold Value of Illumination Change 5 1 16 Continuous Mode Decode Session Timeout 3 000ms Applicable to Sense mode and Continuous mode 100 3 600 000ms 0...

Page 160: ...ssage Off None 0 7 characters Prefix Suffix Prefix Sequence Custom Prefix Code ID AIM ID Custom Prefix Disabled None AIM ID Prefix Disabled Code ID Prefix Disabled Custom Suffix Disabled None Terminat...

Page 161: ...e 128 Enabled Maximum Length 127 Minimum Length 1 GS1 128 UCC EAN 128 GS1 128 Enabled Maximum Length 127 Minimum Length 1 AIM 128 AIM 128 Enabled Maximum Length 127 Minimum Length 1 EAN 8 EAN 8 Enable...

Page 162: ...Required Do Not Require Add On Code EAN 13 Beginning with 434 439 Add On Code Required Do Not Require Add On Code EAN 13 Beginning with 977 Add On Code Required Do Not Require Add On Code EAN 13 Begi...

Page 163: ...On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required System Character Transmit Country Code Do not transmit Interleaved 2 of 5 Interleaved 2 of 5 Enabled Check Character Verificatio...

Page 164: ...racter Do not transmit Maximum Length 127 Minimum Length 6 Standard 2 of 5 Standard 2 of 5 Enabled Check Character Verification Disabled Check Character Do not transmit Maximum Length 127 Minimum Leng...

Page 165: ...de 93 Enabled Check Character Verification Enabled Check Character Do not transmit Maximum Length 127 Minimum Length 3 GS1 Databar GS1 Databar Enabled Application Identifier 01 Transmit Code 11 Code 1...

Page 166: ...Encoding PDF417 ECI Output Enabled QR Code QR Code Enabled Micro QR Enabled Maximum Length 7089 Minimum Length 1 QR Twin Code Read single QR only Character Encoding Default Character Encoding QR ECI...

Page 167: ...o not transmit check character after verification ITF 6 I1 Transmit check character I3 Do not transmit check character ITF 14 I1 Transmit check character I3 Do not transmit check character Industrial...

Page 168: ...ns Data Matrix d0 ECC000 ECC140 d1 ECC200 d2 ECC200 FNC1 is the 1st or 5th character after the start character d3 ECC200 FNC1 is the 2nd or 6th character after the start character d4 ECC200 ECI includ...

Page 169: ...EAN 8 d EAN 13 d ISSN n ISBN B UPC E c UPC A c Interleaved 2 of 5 Febraban e ITF 6 e ITF 14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 Code 32 b Codabar a Code 93 i Code 11 H Ples...

Page 170: ...eed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC...

Page 171: ...llar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Left Opening Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward...

Page 172: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 9...

Page 173: ...0 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122...

Page 174: ...he image stabilization timeout to 500ms 1 Scan the Enter Setup barcode 2 Scan the Image Stabilization Timeout barcode from the Image Stabilization Timeout section in Chapter 3 3 Scan the numeric barco...

Page 175: ...Save barcode 5 Scan the Exit Setup barcode If you still need to program other parameter feature skip this step e Program the Timeout between Decodes Example Set the timeout between decodes to 500ms 1...

Page 176: ...Specify Decoding Area section in Chapter 4 10 Scan the numeric barcodes 2 and 0 11 Scan the Save barcode 12 Scan the Right of Decoding Area barcode from the Specify Decoding Area section in Chapter 4...

Page 177: ...ble p 70 2 Scan the Enter Setup barcode 3 Scan the Modify PDF417 Code ID barcode from the Modify Code ID section in Chapter 6 4 Scan the numeric barcodes 7 and 0 5 Scan the Save barcode 6 Scan the Exi...

Page 178: ...mple Set the scanner to decode Code 128 barcodes containing between 8 and 12 characters 1 Scan the Enter Setup barcode 2 Scan the Set the Minimum Length barcode from the Set Length Range for Code 128...

Page 179: ...cter Encoding barcode according to the symbology your application needs from the Character Encoding section in Chapter 8 4 Scan the Mode 3 barcode from the Emulate ALT Keypad section in Chapter 2 5 Sc...

Page 180: ...2 Scan the Set Transmit Delay per Character barcode from the Transmit Delay section in Chapter 8 3 Scan the numeric barcode 5 4 Scan the Save barcode 5 Scan the Enable Transmit Delay per Character ba...

Page 181: ...167 Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...

Page 182: ...168 A F A B C D E F...

Page 183: ...st Digit barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you...

Page 184: ...VT Vertical Tab 0B Vertical Tab Ctrl K FF Form Feed 0C Delete Ctrl L CR Carriage Return 0D Enter Ctrl M SO Shift Out 0E Insert Ctrl N SI Shift In 0F Esc Ctrl O DLE Data Link Escape 10 F11 Ctrl P DC1...

Page 185: ...B 1C 1D 1E 1F United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl Ctrl Ctrl 6 Ctrl I...

Page 186: ...172 Appendix 9 Code Pages List Numeric Barcode Needed Code Page 0 Windows 1252 Latin I 1 Windows 1251 Cyrillic...

Page 187: ...06 UPC A 007 Interleaved 2 of 5 Febraban 008 ITF 14 009 ITF 6 010 Matrix 2 of 5 011 Code 39 Code 32 013 Codabar 015 Code 93 017 AIM 128 020 ISSN 023 ISBN 024 Industrial 25 025 Standard 25 026 Plessey...

Page 188: ...emont Blvd Fremont CA 94538 USA Tel 510 490 3888 Fax 510 490 3887 Email info newlandna com Web www newlandamerica com Newland Latin America Tel 1 239 598 0068 Fax 1 239 280 1238 Email info newlandla c...

Reviews: