Newland NLS-EM1395-LD Integration Manual Download Page 13

 

Chapter 3 Electrical Specifications 

Power Supply 

Do  not  power  up  the  EM1395-LD  until  it  is  properly  connected.  Be  sure  the  power  is  cut  off  before 

connecting  a  flexible  cable  to  or  disconnecting  a  flexible  cable  from  the  host  interface  connector. 

Hot-plugging could damage the engine. 

Unstable  power  supply  or  sharp  voltage  drops  or  unreasonably  short  interval  between  power-ons  may 

lead to unstable performance of the engine. Do not resupply the power immediately after cutting it off. The 

minimum interval must exceed 500ms. 

The EM1395-LD itself does not provide a power switch. Users can switch the engine off by cutting off the 

power. 

The EM1395-LD

’s start-up time is less than 200ms. 

 

Ripple Noise 

Image sensor and decoder chip are directly fed by the input power of EM1395-LD. To ensure the stable 

performance, a power supply with low ripple noise is needed.   

Acceptable ripple range (peak-to-peak) : 

100mV (

50mV recommended). 

Summary of Contents for NLS-EM1395-LD

Page 1: ...NLS EM1395 LD OEM Scan Engine Integration Guide...

Page 2: ...unction or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujian...

Page 3: ...Revision History Version Description Date V1 0 0 Initial release May 13 2014...

Page 4: ......

Page 5: ...iderations 2 Installation Orientation 2 Optics 3 Window Placement 3 Window Material and Color 3 Scratch Resistance and Coating 4 Window Size 5 Ambient Light 5 Eye Safety 5 Mounting 6 Front View unit m...

Page 6: ...erfaces 9 Host Interface Connector 9 Dimensions of the Host Interface Connector unit mm 9 FFC Cable unit mm 10 Communication Interface 11 Trigger 11 Beeper 13 Good Read LED 14 Chapter 5 Development To...

Page 7: ...Codabar Code 128 Code 93 ITF 6 ITF 14 Interleaved 2 of 5 Industrial 2 of 5 Standard 2 of 5 Matrix 2 of 5 GS1 Databar Code 39 Code 11 MSI Plessey Plessey Illumination The EM1395 LD has a red LED 622 n...

Page 8: ...onment The following environmental requirements should be met to ensure good performance of the EM1395 LD Operating Temperature 20 60 Operating Temperature 40 85 Humidity 5 95 non condensing Thermal C...

Page 9: ...de the reading performance The window should be mounted close to the front of the engine parallel The maximum distance is measured from the front of the engine housing to the farthest surface of the w...

Page 10: ...ectral transmission lowest haze level and homogeneous refractive index It is suggested to use PMMA or optical glass with spectral transmittance over 90 and haze less than 1 Whether to use an anti refl...

Page 11: ...ent lights using 50 60Hz AC power However high frequency pulsed light can result in performance degradation Eye Safety The EM1395 LD has no lasers It uses a red LED to create aiming and illumination b...

Page 12: ...below show the mechanical mounting dimensions for the EM1395 LD The structural design should leave some space between components and reserve enough room for the FFC cable Front View unit mm Top View...

Page 13: ...al between power ons may lead to unstable performance of the engine Do not resupply the power immediately after cutting it off The minimum interval must exceed 500ms The EM1395 LD itself does not prov...

Page 14: ...ximum Unit VDD Voltage Drain Drain 3 0 3 3 3 6 V VIH High Level Input Voltage 0 7 VDD V VIL Low Level Input Voltage 0 2 VDD V VOH High Level Output Voltage 0 9 VDD V VOL Low Level Output Voltage 0 1 V...

Page 15: ...erential data signal 7 USB_D I O USB_D differential data signal 8 PWRDWN O Low Power State signal output Active high indicates that the engine is in low power state 9 Buzz O Beeper output For the info...

Page 16: ...of the Host Interface Connector unit mm The engine uses a 12 pin ZIF socket bottom contact model 10051922 1210ELF 10051922 1210EHLF manufactured by FCI The socket can be connected to a host device wit...

Page 17: ...Based on USB connection the engine s transmission is simulated as USB keyboard input It works on a Plug and Play basis and no driver is required USB COM Port Emulation The USB port on the host device...

Page 18: ...st If the trigger is released during a scan attempt the EM1395 LD immediately stops decoding Next decode session does not happen until the EM1395 LD receives active trigger signal driving the nTrig pi...

Page 19: ...iver circuit for generating audible feedback to the user to indicate statuses like power up or good decode The PWM output is not strong enough to drive a beeper thus a beeper driver circuit is needed...

Page 20: ...dicate a Good Read status When a good read occurs the LED pin produces a high level output for about 300ms then the signal is back to a low level This Good Read LED output is not strong enough to driv...

Page 21: ...eeper driver circuit LED LED driver circuit trigger reset buttons TTL 232 to RS 232 converter TTL 232 to USB converter RS 232 USB interfaces etc The EM1395 LD can be connected to the EVK via a 12 pin...

Page 22: ...wland id com WEB www newland id com Tech Support tech support newland id com Newland North America Inc Address 46559 Fremont Blvd Fremont CA 94538 USA TEL 510 490 3888 Fax 510 490 3887 Email info newl...

Reviews: