Summary of Contents for L400MD04C1A01

Page 1: ...IPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0 10V 1 10V NOT ISOLATED PASSIVE PUSH MODE DALI MODE BLUETOOT...

Page 2: ...cidental contact is garantied by the enclosure Power Connector Cross section of conductors 14 30 AWG 0 05 2 08 mmq Interface Connector Cross section of conductors 15 30 AWG 0 05 1 65 mmq Output Curren...

Page 3: ...User Manual L400MD04C1A01 Use only in dry conditions 3 NEWLAB User Manual L400MD04C1A01...

Page 4: ...LS MAX OUTPUT POWER CONTROL INPUTS CASE DIMENSION mm L400MD04C1A01 8 53V DC from 0 17A to 1 05A 1 54 6W at 52V DC Insulated Push button x1 DALI x1 Linear Potentiometer 100K x1 0 10V Passive x1 1 10V P...

Page 5: ...o the polarity showed in FIG 1 through the DC IN and terminals In case the power supply polarity is inverted no damage will be caused to the device The LED LED PWR positioned on the circuit board indi...

Page 6: ...lue of less than 5 Kohm is interpreted as load off The maximum brightness value is reached by exceeding the value of 95 Kohm In case the potentiometer is disconnected the dimmer sets the output to the...

Page 7: ...follows a logarithmic trend proportional to the control voltage A voltage value of less than 1V is interpreted as load off In case the 0 10V 1 10V signal is disconnected the dimmer sets the output to...

Page 8: ...ization is needed for the input signal The maximum current absorbed by the PUSH interface is about 2mA The dimmer saves the output position in order to restore the set level in case of power failure p...

Page 9: ...MODE THE BLE Bluetooth CONTROL IS FORBIDDEN Below you can find the implemented standard commands DIRECT ARC POWER OFF UP DOWN STEP UP STEP DOWN RECALL MAX LEVEL RECALL MIN LEVEL STEP DOWN AND OFF ON A...

Page 10: ...CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME FADE RATE QUERY SCENE LEVEL 0 15 QUERY GROUPS 0 7 QUERY GROUPS 8 15 QUER...

Page 11: ...group together and control several light points with just a simple command Creation and recall of your favourite lighting sceneries The system management from a single simplified user interface THE B...

Page 12: ...pplication As an alternative you can download the app by clicking on one of two links below Apple https itunes apple com it app newlab go id1151044984 mt 8 Android https play google com store apps det...

Page 13: ...OFF OFF 235 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON 250 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF 260 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON 270 mA OFF ON...

Page 14: ...OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON 761 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF OFF 775 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF ON 788 mA OFF ON OFF OFF OFF OFF OFF OFF...

Reviews: