Summary of Contents for L400MC04T1A01

Page 1: ...IPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0 10V 1 10V NOT ISOLATED PASSIVE PUSH MODE DALI MODE BLUETOOT...

Page 2: ...pped with earth connection Protection against accidental contact with live parts is garantied by the enclosure Power Connector Cross section of conductors 14 30 AWG 0 05 2 08 mmq Interface Connector C...

Page 3: ...ecurity level All connections must be made with non live devices and carried out by specialized personnel If the control voltage of the PUSH input is higher than the SELV voltage it is necessary to us...

Page 4: ...UT CHANNELS MAX OUTPUT POWER CONTROL INPUTS CASE DIMENSION mm L400MC04T1A01 8 53V DC 12A 1 576W at 48V DC Insulated Push button x1 DALI x1 Linear Potentiometer 100K x1 0 10V Passive x1 1 10V Passive x...

Page 5: ...o the polarity showed in FIG 1 through the DC IN and terminals In case the power supply polarity is inverted no damage will be caused to the device The LED LED PWR positioned on the circuit board indi...

Page 6: ...lue of less than 5 Kohm is interpreted as load off The maximum brightness value is reached by exceeding the value of 95 Kohm In case the potentiometer is disconnected the dimmer sets the output to the...

Page 7: ...follows a logarithmic trend proportional to the control voltage A voltage value of less than 1V is interpreted as load off In case the 0 10V 1 10V signal is disconnected the dimmer sets the output to...

Page 8: ...ization is needed for the input signal The maximum current absorbed by the PUSH interface is about 2mA The dimmer saves the output position in order to restore the set level in case of power failure p...

Page 9: ...MODE THE BLE Bluetooth CONTROL IS FORBIDDEN Below you can find the implemented standard commands DIRECT ARC POWER OFF UP DOWN STEP UP STEP DOWN RECALL MAX LEVEL RECALL MIN LEVEL STEP DOWN AND OFF ON A...

Page 10: ...CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME FADE RATE QUERY SCENE LEVEL 0 15 QUERY GROUPS 0 7 QUERY GROUPS 8 15 QUER...

Page 11: ...e command Creation and recall of your favourite lighting sceneries The system management from a single simplified user interface THE BLUETOOTH LE CONNECTION DOES NOT REQUIRE PAIRING PROCEDURE Newlab G...

Page 12: ...pplication As an alternative you can download the app by clicking on one of two links below Apple https itunes apple com it app newlab go id1151044984 mt 8 Android https play google com store apps det...

Page 13: ...OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Linear OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON PWM Configuration A B C D 1 2 3 4 5 6 7 8 9 10 PWM Standard OFF OFF ON OFF OFF OFF OFF OFF OFF OFF...

Reviews: