7 Error List
7.3 Event messages
174
FST_HB.EN12/05
7.3 Event messages
Code
Message
Description
Reason
128
COLDSTART
Power supply of the FST-2 was
interrupted and is back on.
-
The FST-2-Controller was
switched off and on again on
the fuse or the main switch.
-
There was a power failure.
129
INSPECTION–ON
INSPECTION–OFF
Inspection work is being carried out.
The inspection switch on the car
roof is set to INSPECTION.
131
POWER LOST
Failure of the 24V power supply.
The system was shut down or
the power supply is faulty.
132
REMOTE RESET
The FST-2-Controller was reset by
the GST Group Controller.
The FST-2-Controller was reset
through the serial interface.
133
CALIBRATION–START
CALIBRATION–OK!
Calibration progress is displayed.
A calibration drive was triggered.
134
LEARN DRIVE–START
LEARN DRIVE–OK!
Learn drive progress is displayed.
A learn drive was triggered.
135
SOFTWARE UPDATE
The software of the FST was
updated with a PC-Card.
136
EVACUATION–ON
EVACUATION–OFF
EVACUATION–OK
An evacuation drive was carried out.
The evacuation signal on a
programmable input/output was
active.
137
X12-SERIAL OK
DCP interface X12 in operation.
The serial DCP interface X11
between FST and frequency
converter was initialised
correctly (e.g. after switching
on).
138
MONITOR SIGNAL–ON
MONITOR SIGNAL–OFF
State change on the programmable
“Monitor” input.
The programmable “Monitor”
input has changed its state. This
input can be used to enter state
changes of any signal in the error
storage (see “Programmable
inputs and outputs” on
page 147).
139
APRON OUT–ON
APRON OUT–OFF
State change on the “Apron
Monitoring” input.
The state of the electronically
monitored apron for small shaft
pits is entered in the error
storage as a message.
140
ORIENTATION
Orientation drive with incremental
positioning.
-
Power failure for more than 30
seconds
-
Power failure with car not in
levelling position
-
Strong discrepancy between
solenoid switch states KO, KU
and Zone B
141
BATTERY–EMPTY
The FST-2 battery is empty and
must be changed.
143
AUXILIARY–
Auxiliary control was switched on or
off.
The auxiliary switch in the control
cabinet was activated.
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...