5 Menu tree
5.2 MAIN MENU – Service
104
FST-2_HB.EN12/05
5.2 MAIN MENU – Service
All menu items with adjustable values can be deactivated by entering the
value “0”.
Menu item
Description
Setting range
Error List
Displays the last 100 error messages (see Chapter 8).
Clear Error List
Delete entries in the error list.
³
YES
NO
Service-Counters –
Clear All Counters
The controller has three internal service counters for drives,
motor hours and door cycles. A service interval can be
allocated to each counter so that a due service is signalled via
a programmable input/output. The counter values for
Motor-Hours
,
Drives
and
Door Cycles
can be
reset here (e.g. after a service).
³
YES
NO
Service-Counters –
Set Interval
Overwrite counter values
To Service
with the values of
the
Interval
counters (e.g. after a service).
³
YES
NO
Service-Counters –
Motor-Hours –
Since Day1
Motor hours since commissioning of the FST-2-Controller.
This value cannot be reset.
Read only
Service-Counters –
Motor-Hours –
Current
Motor hours since last
Clear All Counters
.
Read only
Service-Counters –
Motor-Hours –
To Service
Motor hours remaining to the next service.
Read only
Service-Counters –
Motor-Hours –
Interval
Motor hours of the maintenance interval.
0 .. 9999 h
Service-Counters –
Drives –
Since Day1
Drives since commissioning of the FST-2-Controller. This
value cannot be reset.
Read only
Service-Counters –
Drives –
Current
Drives since last
Clear All Counters
.
Read only
Service-Counters –
Drives –
To Service
Drives remaining to the next service.
Read only
Service-Counters –
Drives –
Interval
Drives of the maintenance interval.
0 .. 99999
Service-Counters –
Door Cycles –
Since Day1
Door cycles since commissioning of the FST-2-Controller.
This value cannot be reset.
Read only
Service-Counters –
Door Cycles –
Current
Door cycles since last
Clear All Counters
.
Read only
Service-Counters –
Door Cycles –
To Service
Door cycles remaining to the next service.
Read only
Summary of Contents for FST-2
Page 6: ...Table of contents 4 FST 2_HB EN12 05...
Page 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Page 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Page 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Page 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Page 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Page 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Page 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Page 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Page 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...