Symptom:
Reason:
Correction:
Spinner will not run
Defective Spinner Control Valve
Replace spinner control valve cartridge and coil�
No voltage at valve
Verify spinner switch is on�
Verify spinner enable is checked�
Verify controller has a target spinner RPM entered�
Check WSM 7�5 amp fuse is not blown�
Verify spinner control harness is not damaged�
Verify system was configured as Basic independent.
No hydraulic flow
Verify hydraulics are on�
Pressure test pump - replace as needed�
System is going over relief - test & replace as needed�
Spinner will not shut off
Defective spinner control valve
Replace spinner control valve cartridge�
Control valve is manually
overrode
Loosen jam nut on control valve cartridge and back
set screw out until spinner stops�
Spinner runs erratic
Defective spinner control valve
Replace spinner control valve cartridge�
Spinner speed sensor harness
failure
Replace sensor harness�
Spinner speed sensor not
properly installed
Adjust sensor so that gap between sensor and fin
mounting bolt is less than 1/8”�
Spinner speed drops off
when turning around
Improper control settings
Verify PWM control is set properly (HOLD for gear
pumps, CONTROL for variable displacement)�
Not applying correct
rate
Incorrect settings
Verify density, swath width, gate opening, encoder
pulses, and CFR number are all adjusted as needed�
No ground speed
Manual speed is enabled, but
set to 0
Enter correct speed or disable manual speed
AUX broadcast speed is
enabled but radar not installed
Disable broadcast AUX speed�
Incorrect speed source is
selected
Select correct speed source�
Spinner speed does not
hit target
Defective spinner control valve
Replace spinner control valve cartridge�
Pump failure
Flow and pressure test pump�
Spinner speed sensor not
properly installed
Adjust sensor so that gap between sensor and fin
mounting bolt is less than 1/8”�
Hydraulic flow dropping off
Adjust settings and speed� Pressure test relief
(adjust or replace as needed)�
Spinner speed sensor harness
failure
Replace sensor harness�
Spinner speed sensor failure
Replace spinner speed sensor�
Summary of Contents for NL345/MULTAPPLIER
Page 6: ...Insert Current New Leader Warranty Warranty...
Page 26: ...26 www NewLeader com 800 363 1771 312884 AA C NL345 Informational Decals 1 1...
Page 86: ...86 www NewLeader com 800 363 1771 312884 AA C NL345 Header Hydraulic Schematic TR3000 Brakes...
Page 114: ...114 www NewLeader com 800 363 1771 312884 AA C NL345 Notes This Page Intentionally Left Blank...