- 128 -
www.NewLeader.com
(800) 363-1771
312884-AA-C
NL345
Feed Gate Alarms
Alarm
Description
Trigger
Feed Gate Not
Calibrated
“Feed Gate must be calibrated prior to
operation�” + [Bin Name]
[Feed Gate Enable/Disable] is Enabled,
equipment profile is active and feed
gate actuator has not been calibrated�
Feed Gate
Movement
“Feed Gate may move at this time�
Please keep clear of feed gate�” + [Bin
Name]
Upon user acknowledgement, dialog
is dismissed and warning flashes
on interval in the status bar until
corresponding feed gate calibration is
complete�
Feed Gate
Movement
During
Calibration
“Feed gate will move during calibration�
Please wait�”
Upon user acknowledgement, system
moves feed gate�
Feed Gate Not
Responding
“Feed Gate not responding�” + [Bin
Name]
Upon user acknowledgement, dialog
is dismissed� System allows product
application at current feed gate position�
Feed Gate
Sensor Outside
Expected
Operating Range
“Feed Gate sensor outside expected
operating range� Check sensor, and
related wiring�” + [Bin Name]
Upon user acknowledgement, dialog
is dismissed� System allows product
application at current feed gate position,
and feed gate control is disabled�
Feed Gate
Position Sensor
Error During
Calibration
Routine
“Lost or intermittent signal from feed
gate position sensor� Check sensor
and related wiring prior to continuing
calibration routine�”
Upon user acknowledgement,
calibration routine is exited�
No Feedback
from Position
Sensor
“No Feedback from Position Sensor�” +
[Bin Name]
Upon user acknowledgement, dialog
is dismissed� System allows product
application at current position�
Feed Gate out of
Position (Position
Sensor Reporting
Wrong Position)
“Feed Gate Out of Position�”
Upon user acknowledgement, dialog
is dismissed� System allows product
application at current position�
Feed Gate Circuit
Disabled
“Feed Gate Circuit Disabled�”
“Pressing acknowledge will enable and
allow feed gate to move� Do you wish to
proceed?”
Upon user acknowledgement, dialog is
dismissed� System sets feed gate circuit
to “Enabled”, Feed Gate movement
dialog is presented and system moves
feed gate to user defined Feed Gate
Height setting�
Controller Operations
Summary of Contents for NL345/MULTAPPLIER
Page 6: ...Insert Current New Leader Warranty Warranty...
Page 26: ...26 www NewLeader com 800 363 1771 312884 AA C NL345 Informational Decals 1 1...
Page 86: ...86 www NewLeader com 800 363 1771 312884 AA C NL345 Header Hydraulic Schematic TR3000 Brakes...
Page 114: ...114 www NewLeader com 800 363 1771 312884 AA C NL345 Notes This Page Intentionally Left Blank...