7 - MAINTENANCE
Air cleaner - Inner element - Replace
1. Pull the outer element
(1)
from the canister. Clean any
loose dirt from the canister and inspect the end of the
canister for dirt which may prevent the new element
from sealing properly.
2. Pull the inner element
(2)
from the canister
3. Install the new inner element by inserting it into the
canister and pushing on the end of the element until
it is seated against the canister.
4. Install the outer element by inserting it into the canister
and pushing on the end of the element until it is seated
against the canister.
NOTE:
If element is not inserted far enough into canister,
the end cap cannot be installed.
5. Place the end cap onto the canister body, push in on
end cap, and rotate clockwise. Make sure the end cap
is locked in place and not loose.
NOTICE:
Failure to obtain a good seal between elements
and the canister may cause major engine damage.