- 40 -
O-ring
Filter element (FE-1)
Filter unit top
Nut
Filter unit (MF-50)
Rotate and
loosen the nut.
Nut
Inlet spacer
9. Consumable Parts Replacement
This product has been designed so that its consumable parts can be easily replaced by the end
user. Contact New Cosmos or its authorized representative for ordering.
9-1. Filter Element Replacement
If the filter element (FE-1) is dirty, replace it with a new one by taking the following steps.
1. Loosen the nut of the filter unit (MF-50) and pull to separate the filter unit
’s top from the inlet.
2. Replace the filter element with a new one.
3. Install the filter unit top to the inlet. Rotate and tighten the nut to secure the tube. Ensure O-ring
is correctly seated.
Tips when removing/reinstalling the entire filter
unit from/into the gas inlet:
Completely remove old sealing tape (no
residue). Wrap new sealing tape around the
threads of the filter unit (approx. 2.5 wraps).
Wrap sealing tape tautly to prevent slack.
Tape size: 13mm (width) x 100
5mm (length) x
0.1mm (thickness)
Tighten the filter unit so that movement of the
spacer is not possible. Do not over tighten the
filter unit to prevent broken inlet.
O-ring must be present.
Rotate and tighten the nut.