Ca p.5

 

–  A PP LI CATIONS  

 

5 . 1

 

–   T h e r a p y   s e s s i o n s  

 

Apply  the  LASER  therapy  according  to  medical  prescriptions

Applications  are  done  every  other  day  or  2-3  days.  Use  the  most  suitable 
program  for  the  patient  until  the  ailment  disappears  or  considerably 
decreases.

 

 

5 . 2

 

–   A d j u s t i n g   e m i s s i o n   p o w e r   o u t p u t    

 

Intensity adjustment is a main component for the good result of the therapy. 
It  differs  based  on  the  type  of  program  being  used,  the  duration  of  the 
application  and  the  characteristics  of  the  patient.  The  intensity  can  be 
changed during the program to increase its affects. It can also be decreased in 
case of overheating or if pain is felt. 

 

The  device  is  endowed  with  a  special  function  that  allows  to  have  safer 
treatments:  it’s  the  “Maximum  power  output”,  you  can  find  it  in  the 
configuration  page,  and  it  allows  to  set  the  maximum  power  output  of  the 
device.  Consequently  during  work  phase  the  sum  of  the  power  of  the 
different sources cannot  exceed the value set during configuration, therefore 
avoiding dangerous power levels during treatment.  
If  inadvertently  the  operator  tries  to  set  higher  values,  the  device 
automatically limits itself. 
The  device  shows  that  the  threshold  has  been  passed  in  two  ways:  if  the 
operator is adjusting the duty cycle, the device limits the power bar and it get 

Summary of Contents for Hi-Laser Beta LASER

Page 1: ...ax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is property of New Age Italia srl All rights are reserved Any copy or reproduction of it through any means including...

Page 2: ...Rev 00 of 14 01 10 2 24...

Page 3: ...mulation 10 2 4 Setting time and intensity of emission 10 2 5 Interrupt end therapy 10 2 6 Turning device off 10 2 7 Configuration 10 Cap 3 PRE SET PROGRAMS 11 Cap 4 FREE PROGRAMS 12 4 1 Setting a new...

Page 4: ...7 9 4 Other features 17 Cap 10 BASIC SUPPLY AND ACCESSORIES 18 10 1 Basic supply 18 10 2 Accessories and consumption material 18 ATTENTION READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE IT IS RECOM...

Page 5: ...lable its experience in the physiotherapy field through the various programs that each appliance owns this enables the operator to be operational and efficient right from the first applications obtain...

Page 6: ...rocirculation One of the effects deriving from using the high power LASER is the distinct vasoactive effect on the microcirculation The activation of the microcirculation entails greater oxygenation a...

Page 7: ...rthritis arthritis arthrosis sciatica lumbago General traumatology articular sprains tendonitis tenosynovitis muscle strains bruises bursitis enthesitis torn muscles pathologies of overload muscular i...

Page 8: ...Cap 2 OPERATION NOTE check the contraindications and follow indications carefully before applying LASER therapy 2 Knob push button 6 Stop button 1 Touch screen display 3 safety key 4 Optical fibre ou...

Page 9: ...erned parameters are type of emitted wave supplied power therapy duration duty cycle of the generated wave 2 2 2 Reset program mode Press START on the initial screen touch screen to access the work ar...

Page 10: ...PRESS THE KNOB repeatedly to pass from the intensity parameter to the time parameter and vice versa The minimum density increase is of 1 and the maximum settable intensity is 100 the minimum time incr...

Page 11: ...ogies which can benefit from the effects of electromagnetic fields chronic pathologies articular problems oedemas etc This chapter lists the programs pre set inside the device LASER has 30 different p...

Page 12: ...phase Press PARAMETERS on touch screen to move the cursor in the work phase setting section In this zone ROTATE THE KNOB to set the parameter value and PRESS THE KNOB to pass from one parameter to an...

Page 13: ...changed during the program to increase its affects It can also be decreased in case of overheating or if pain is felt The device is endowed with a special function that allows to have safer treatment...

Page 14: ...k or facedown depending on the zone of application This position must be maintained during the entire session to facilitate the effects produced by the laser beam especially the increased the blood fl...

Page 15: ...r or other parts are damaged broken or missing it appears that the features of the device have been changed for safety purposes do not operate with accessories e g knobs and power supply other than th...

Page 16: ...rature between 5 and 40 C and less than 80 humidity The same conditions must be maintained during transportation and storage In case of malfunctioning and failures do not use the device but send it to...

Page 17: ...standards EN 60601 1 1 2003 Collateral safety standard EN 60601 1 2 2003 Collateral standard Electromagnetic compatibility Provisions and tests EN 60601 1 4 1997 Collateral standard Programmable elect...

Page 18: ...e goggles for the patient N 1 knob 1 power cable 1 User manual N 1 Trolley 1 0 2 A c c e s s o r i e s a n d c o n s u m p t i o n m a t e r i a l The following is the list of accessories which can be...

Reviews: