–   S w i t c h   o f f   o f   t h e   d e v i c e  

 

To switch off the device  hold pressed the key (The)  ON/OFF for some seconds. If 
after  the  expiration    of  a  program  the  instrument  is  not  used,  it  switches  off  
automatically    after    few  minutes.  At  the  end  of  the  session  disconnect  the  cables 
from the device and  put back all the accessories in the handbag. Preserve in a cool 
and dry place. 

 

Ca p.4

 

–   I N F R A R E D   T H E R A P Y  

 

–   P r o g r a m s    

 

BIOLASER has 20 preset programs ready to be used. 
 

4.1.1

 

– PRESET PRO GRAM S  

 

The preset programs are listed in the table below.

 

 

BIOLASER programs table 

 

N° Prog.  Name on display 

Pathology to be treated 

P.1

 

 

Cervical 

Cervical 

P.2

 

 

Pubalgy 

Pubalgy 

P.3

 

 

Dorsalgia 

Dorsalgia / Bone pain 

P.4

 

 

Lumbago 

Lumbago   

P.5

 

 

Epicondilitis 

Epicondilitis 

P.6

 

 

Tunn. Carp. 

Tunnel carpale 

P.7

 

 

Metatarsalg. 

Metatarsalgia / /Fascitis 

P.8

 

 

Inflammation 

Inflammation / Sciatica 

P.9

 

 

Contusions 

Contusioni / Edemas 

P.10

 

 

Distorsions 

Distorsions (knee/ankle) 

P.11

 

 

Periartrhritis 

Periartritis of shoulder 

P.12

 

 

Arthritises 

Arthritises / Arthrosis 

P.13

 

 

Sprains 

sprains / muscular Pains 

P.14

 

 

Bursities 

Bursities 

P.15

 

 

Tendinitis 

Tendinitis 

P.16

 

 

Contractures 

Muscular contractures 

P.17

 

 

Tears 

Tears / muscular Pains 

P.18

 

 

Cellulitis 

Cellulitis / Swelling / Sore / Acne / Scars / Warts / 

P.19

 

 

Acute pains 

All the acute pains 

P.20

 

 

Chronic pains 

All the chronic pains 

Summary of Contents for BIOLASER

Page 1: ...545 32019 Telefax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is the property of New Age Italia All rights are reserved This document may not be copied or reproduc...

Page 2: ...ns 5 Side Effects 5 Cap 3 Operation 6 Connection to the electric net 6 Connection of the handle 7 Application of the handle 7 Switch on of the device 7 Selection of the program 7 Intensity of emission...

Page 3: ...3 Immediate maintenance 10 Cap 7 11 Cap 8 CAUTION 11 Cap 9 TECHNICAL CHARACTERISTICS 12 Supply 12 Output characteristics 12 Other characteristics 12 Cap 10 SYMBOLS 13 Cap 11 STANDARD ENDOWMENT AND AC...

Page 4: ...rough the use of the presetted programs contained in its memory and the 20 free programs Thanks to BIOLASER therefore it is possible to apply the infrared therapy with standard programs and to have th...

Page 5: ...ects with pace maker neoplasie tumori pregnancy in progress epilepsy photosensitivity children areas of growth S i d e E f f e c t s Cutaneous burns if the intensity is notable and if are present diso...

Page 6: ...modulation 6 ON OFF 7 Cable output 8 UP DOWN program selection timer adjustment C o n n e c t i o n t o t h e e l e c t r i c n e t BIOLASER can be used with battery or fed to electric current connec...

Page 7: ...he program with the keys UP DOWN see section Programs and confirm with START The programs are listed in the charts in Preset protocols I n t e n s i t y o f e m i s s i o n The intensity of the emissi...

Page 8: ...IOLASER programs table N Prog Name on display Pathology to be treated P 1 Cervical Cervical P 2 Pubalgy Pubalgy P 3 Dorsalgia Dorsalgia Bone pain P 4 Lumbago Lumbago P 5 Epicondilitis Epicondilitis P...

Page 9: ...am Repeat the operation so that to apply the therapy on the whole interested surface 4 2 S e s s i o n s Apply the laser therapy 3 4 times a week at alternate days up to the disappearance or appreciab...

Page 10: ...example if left next to intense heat sources you doubt that some liquids can be penetrated inside the wrap or other parts of the instrument are damaged broken or lacking the functionality of the instr...

Page 11: ...nd with a surgical instrument HF to avoid dangers for the patient and for the same instrument Don t use in presence of equipments for the monitoring of vital parameters The tool works according to its...

Page 12: ...c s Dimensions 225x170x120h mm Weight 1000 g approx Class I Tipo BF Class II Tipo BF Classification in comparison to the entry of liquids IP20 Safety in presence of inflammable anaesthetic gas it is n...

Page 13: ...DEVICE IS MARKED AT THE SENSES OF THE 0476 DIRECTIVE CEE 93 42 Cap 11 STANDARD ENDOWMENT AND ACCESSORIES B a s i c e n d o w m e n t BIOLASER is complete with Device Handle at 9 diods Protective goggl...

Page 14: ...d Minerva Medica Torino 1993 B Gialanella G D alessandro R Santoro Terapia fisica pratica ED Marrapese Roma 1997 A Vasta Manuale pratico illustrato di terapia fisica ED Marrapese Roma 1998 C Cisari G...