User Manual – Gigabit PoE Supply NPS-30W | BDA 579 V2 2020/06

Safety

2.3.1 Declaration of conformity

The device meets all the relevant EU directives and therefore has the CE and EAC marking. The 
Declaration of Conformity may be viewed at https://www.neutrik.com/en/support/downloads.

2.4 Important safety instructions

Avoid property damage to the Gigabit PoE Supply due to unsuitable operating and environmental 
conditions:

 

Never immerse in water.

 

Protect from strong sunlight.

 

Never install the device near heat sources such as radiators, heating units, ovens or stoves.

 

To avoid overheating, never cover the device.

 

Protect the device from impact and above all, from falling from poles, stages, tables or furniture.

Repair

 

w

NOTE

Property damage due to improper repair!

The Gigabit PoE Supply does not contain any parts that you can repair yourself. Opening or re-
pairing the device on your own may result in severe damage to the device.

 

T

Do not open the housing of the Gigabit PoE Supply under any circumstances.

 

T

Do not change any parts yourself.

 

T

Only have the Gigabit PoE Supply repaired by a authorized specialist dealer.

Information for operation

 

T

Ensure that the ambient conditions specified for the Gigabit PoE Supply is observed during 
operation.

 

T

Do not use the Gigabit PoE Supply if it is not functioning properly, has fallen or been damaged, 
has become wet or if parts of it have been immersed in water.

 

T

If disruptions occur during operation: 
Immediately disconnect the Gigabit PoE Supply from main.

 

T

Do not operate the Gigabit PoE Supply in environments where flammable or explosive materials, 
gases or vapors are present or might occur.

2.5 Intended use

The Gigabit PoE Supply is a Gigabit power supply used to supply power and transmit data over 
Ethernet

2.6 Foreseeable improper use

The Gigabit PoE Supply is not suitable for use outdoors and in potentially explosive atmospheres.

Summary of Contents for NPS-30W

Page 1: ...User Manual NPS 30W Gigabit PoE Supply...

Page 2: ...ed by copyright The user manual must not be duplicated reproduced microfilmed or translated nor must it be converted to be saved and processed in IT systems neither in the form of excerpts nor in full...

Page 3: ...it PoE Supply 9 4 2 Device 9 4 3 Connections and displays 9 4 3 1 Overview front 9 4 3 2 Overview rear 10 5 Operation 11 5 1 Preparations 11 5 2 Connecting devices with the Gigabit PoE Supply 11 5 3 A...

Page 4: ...uture owner of the product T If this user manual is lost or damaged a copy of it can be downloaded from the Neutrik s website www neutrik com 1 2 Designations Designation Explanation Gigabit PoE Suppl...

Page 5: ...the action steps in the order they are presented The result of the action or the reaction of the product to the action are depicted with this symbol Lists without a mandatory sequence are presented as...

Page 6: ...Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and may radiate radio frequency energy and if...

Page 7: ...ng or re pairing the device on your own may result in severe damage to the device T Do not open the housing of the Gigabit PoE Supply under any circumstances T Do not change any parts yourself T Only...

Page 8: ...ries can be ordered separately Pos Description Item no 1 Gigabit PoE Supply NPS 30W NPS 30W 2 Mounting brackets Kit includes 2 brackets 2 fixing screws 2 torx screws and 2 spacers NA MB KIT 3 Rack pan...

Page 9: ...bit PoE Supply is designed for harsh stage conditions and offers a reliable solution for pow ering various devices With optional accessoires it offers several mounting options including truss mount ra...

Page 10: ...ion 1 Data in connection RJ45 Used for the unpowered data transmission between Gigabit PoE Supply and a network device 2 Power in connection PowerCON TRUE1 AC 100 240 V 50 60 Hz max 0 75 A power conne...

Page 11: ...or higher it is mandatory to use AWG24 or higher cross section cables For cable lengths of 50 m or longer it is mandatory to use AWG24 or higher cross section cables F UTP Kat 6A cables are recommend...

Page 12: ...2 User Manual Gigabit PoE Supply NPS 30W BDA 579 V2 2020 06 Operation Front Rear 5 3 Applications NPS 30W Gigabit PoE Supply PoE PWR LAN Power IN www neutrik com AC 100 240 V 5 0 6 0 H z m a x 0 7 5 A...

Page 13: ...cause a damage due to different pin assignment 5 3 1 Power and Data Redundancy Example using NA2 IO DPRO For Power and Data Redundancy 2 NPS 30W PoE Supplies are required 5 3 2 Daisy chaining Data onl...

Page 14: ...sy chained with one NPS 30W Example using NA2 IO DPRO and NA2 IO DLINE 5 4 Accessories assembly instructions Data only Power only Power Data Dante ready mixing desk DPRO controller PRIMARY PRIMARY SEC...

Page 15: ...ckets 2 brackets 2 fixing screws 2 torx screws 2 spacers 1 T Remove the rubber protection 2 T Mount a bracket a spacer and a screw on the device as shown on the picture T Tighten the screw with the sc...

Page 16: ...nel NRP1RU 2A Scope of delivery 1 rack panel 1 2 T Remove the rubber protection T Place the device in the rack panel T Fix the device with the four screws T Remove the 4 screws on the front of the dev...

Page 17: ...KIT Scope of Delivery 2 fixing screws 2 safety frames 1 yoke mount 4 cross screws Assembling the trussmount Prepare the following tools O Crosshead screwdriver T Use the existing screws M3 x 6 mm to...

Page 18: ...stances T Never spray device or accessory with liquids under any circumstances T Wipe the surfaces of the device and accessory with a soft cloth slightly moistened with a mild soap solution T Never us...

Page 19: ...ns T Never dispose of electrical devices or electrical accessories such as cables plugs batteries or components with household wastes under any circumstances T Dispose of packaging and packaging eleme...

Page 20: ...hernet and describes a practice for using a single CAT5e or higher to incorporate both power and data in the single cable Few advantages Easy setup Single cable run up to 100 m Using PoE doesn t requi...

Page 21: ...is a process of PSE determining the power requirements of the PD Once PD and PSE are connected PSE sends out a short voltage impulse reads the returned value and provides power accordingly This is val...

Page 22: ...22 User Manual Gigabit PoE Supply NPS 30W BDA 579 V2 2020 06...

Reviews: