background image

First slide the housing onto the cable and 

insert the sealing cap       into the other hole.

A

Prepare the cable by stripping 25 mm of the 

jacket.

Reduce the shielding strands to a length 

of 7 mm and bend them over the jacket. 

Shorten the wires and strip the insulation as 

indicated in figure 2.

Slide the prepared end of the cable into 

the open end of the plug, so that 9 mm of 

unstripped cable rests inside the plug.

Next crimp the end of the plug with a 

standard 6.35 mm hexagonal crimping tool 

(RG 58).

Crimp only in the area designated in 

figure 4!

_

figure 2

figure 3

figure 4

figure 1

NE

UT

RI

K

NP3

TT-

2

A

7

15

15

20

20

25

25

10

10

3

T1

R1

T2

R2

Dual Plug NP3TT-2