Summary of Contents for ZB11C

Page 1: ...Motion Detector with On Off Switch and Temperature Sensor User Manual Model ZB11C FW V1 1 HW V0 2 20130605...

Page 2: ...11C Light sensitivity adjustor Binding Key Red green indicator Infrared red Sensor Click in pit Related Netvox devices 9 Power outlet Z80x series 9 Security Z601A Z210 Z201B CIE Auxiliary Key Sensor s...

Page 3: ...otification to the network for specific application What is ZigBee ZigBee is a short range wireless transmission technology which defined for a minimum complexity low power consumption low data rate c...

Page 4: ...ion 9 Fully IEEE 802 15 4 compliant 9 Utilizes 2 4GHz ISM band up to 16 channels 9 Up to 70 meters non obstacle wireless distance 9 Simple operation and device configuration 9 Power supply 2 x ER14505...

Page 5: ...r on the ZB11C will flash 5 times in green if successful otherwise the indicator stays dark Repeat the process if join attempt failed ZB11C is an end device which goes to sleep To wake up the device f...

Page 6: ...is out of network it will wake up every 15 minutes to find the network it joined before It never goes to deep sleep but continues to find its network every 15 minutes This scenario can consume up to 5...

Page 7: ...tem or called CIE security system device Control Indication Equipment in the network to trigger a siren or a silent alarm This device will require security zone registration enrollment On Off for exam...

Page 8: ...2 Within 5 seconds short press on the binding key once for motion detector binding twice for lighting control binding 3 times for temperature report binding If pairing successful the green LED indicat...

Page 9: ...r switch devices The 120 seconds countdown timer will start followed by a turn ON command sent The light sensor sensitivity threshold can be adjusted to fit your need From the light sensitivity adjust...

Page 10: ...ured to be an end device and is designed to enter temporal sleep after idle to save battery power Sometimes during system setup you would want to retrieve information i e IEEE address short address fr...

Page 11: ...e how far and wide does ZB11C actually detect especially for security system installation Operation To force the device to run in the zone detection mode hold press the auxiliary key for 3s release wh...

Page 12: ...ea A has the farthest distance of 11 meters with view angle of 30 degrees The coverage area B has the mid range distance of 8 meters with view angle of 60 degrees The coverage area C has the shortest...

Page 13: ...Next Page Device Attributes Description for developers only...

Page 14: ...of ZB11C EP 0x01 Server side Client side Mandatory Basic 0x0000 Identify 0x0003 Ias Zone 0x0500 Commissioning 0x0015 Identify 0x0003 EP 0x02 Server side Client side Mandatory Basic 0x0000 On Off Switc...

Page 15: ...HWVersion Unsigned 8 bit integer 0x00 0xff Read only O 0x0004 ManufacturerName Character string 0 32 bytes Read only netvox O 0x0005 ModelIdentifier Character string 0 32 bytes Read only O 0x0006 Date...

Page 16: ...Our ZiG BUTLER allows you to do that Of course any other 3rd party ZigBee enabled software is also applicable ZiG BUTLER software is to be installed on a PC or a server The system needs a Z103 USB do...

Page 17: ...should see the ZB11C device icon appeared in ZiG BUTLER Device Pairing Configuring You are able to program and pair two devices through ZiG BUTLER Part A For power switch pairing for temperature go to...

Page 18: ...lly a lighting device or a power outlet device Under Cluster column label B look for 0006 On Off Make sure the empty box next to must be ticked If you do not see 0006 On Off you can obtain it from a p...

Page 19: ...previous figure and the system will pair the interface Before you click on OK make sure you wakeup the ZB11C device so that the setting can be written into it Figure 2 Binding successful Figure 3 Bind...

Page 20: ...ppear similar to the one bellow Under the Device tab label A select the device to be paired normally an interface device Under Cluster column label B look for temperature measurement Make sure the emp...

Page 21: ...the system will pair the interface Before you click on OK make sure you wakeup the ZB11C device so that the setting can be written into it Figure 2 Binding successful Figure 3 Binding unsuccessful Zi...

Page 22: ...seconds between issuing temperature reports If this value is set to 0 then the device shall not report the temperature Reportable change this is the minimum temperature change that will result in a r...

Page 23: ...o check Auto to enable the feature configured or to uncheck it to disable Then click Set to send the configured information to the ZB11C device Please refer to Notice bellow Notice Recall that the ZB1...

Page 24: ...n dialog screen appears similar to the one bellow In this figure for example the paired light device is listed in the Devices Bound list If you have doubt that the list is incorrect please wake up the...

Page 25: ...is able to reassign the zone device to another CIE device in the network Select a CIE device from the dropdown menu then click on Set IAS_CIE_ADDRESS button When successfully registered to the new CIE...

Page 26: ...View enrolled zone device table All the enrolled zones are listed in the zone table as shown in the figure bellow The table shows the IAS Zone 01 has enrolled...

Page 27: ...a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and c...

Page 28: ...e with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause...