8
5.1 ConfigureCmd
Fport : 0x07
(1)
Command Configuration:
MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink
:
01AA003C003C0100000000 003C(H
ex)
= 60(D
ec)
Response
:
81AA000000000000000000
(
Configuration success
)
81AA010000000000000000
(
Configuration failure
)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
ConfigReport
Req
R311LA
0x01
0xAA
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed
0x00)
ConfigReport
Rsp
0x81
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes, Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit: s)
MaxTime
(2bytes Unit: s)
BatteryChange
(1byte Unit: 0.1v)
Reserved
(4Bytes, Fixed
0x00)
SetOnDistance
ThresholdRreq
0x03
OnDistanceThreshold
(2byte )
Reserved
(7Bytes, Fixed 0x00)
SetOnDistance
ThresholdRrsp
0x83
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetOnDistance
ThresholdRreq
0x04
Reserved
(9Bytes, Fixed 0x00)
GetOnDistance
ThresholdRrsp
0x84
OnDistanceThreshold
(2byte )
Reserved
(7Bytes, Fixed 0x00)